cpclean - Remove wrong control points by statistical methods
cpclean [options] input.pto
cpclean uses statistical methods to remove wrong control points.
Step 1 optimises all images pairs, calculates for each pair mean
and standard deviation and removes all control points with error bigger than
mean+n*sigma.
Step 2 optimises the whole panorama, calculates mean and standard
deviation for all control points and removes all control points with error
bigger than mean+n*sigma.
- --output|-o output.pto
- Output Hugin PTO file. Default: '<filename>_clean.pto'.
- --max-distance|-n num
- distance factor for checking (default: 2)
- --pairwise-checking|-p
- do only pairwise optimisation (skip step 2)
- --whole-pano-checking|-w
- do optimise whole panorama (skip step 1)
- --dont-optimize|-s
- skip optimisation step when optimising the whole panorama
- --check-line-cp|-l
- also include line control points for calculation and filtering in step
2
- --help|-h
- shows help