|
|
| |
ipmitool - utility for controlling IPMI-enabled devices
ipmitool [ <options> ] <command> [ <sub-commands and
sub-options> ]
<options> := [ <general-options> |
<conditional-opts> ]
Any recognized option is accepted. Conditional options may be ignored or it's
usage postponed until shell or exec processes relevant command.
<general-options> := [ -h | -V | -v | -I <interface> |
-H <address> |
-d <N> | -p <port> | -c | -U <username> |
-L <privlvl> | -l <lun> | -m <local_address> |
-N <sec> | -R <count> | <password-option> |
<oem-option> | <bridge-options> ]
<conditional-opts> := [ <lan-options> |
<lanplus-options> |
<command-options> ]
Bridging:
<bridge-options> := -t <target_address> [ -b <channel> |
[ -T <address> | -B <channel> ] ]
Options used with -I lan:
<lan-options> := [ -A <authtype> ]
Options used with -I lanplus:
<lanplus-options> := [ -C <ciphersuite> | <key-option> ]
Option groups setting same value:
<key-option> := [ -k <key> | -K | -y <hex_key> | -Y ]
<password-option> := [ -f <password_file> | -a | -P
<password> | -E ]
<oem-option> := [ -o <oemtype> | -g | -s ]
Options used with specific command <command-options>:
<options-sdr> := [ -S <sdr_cache_file> ]
<options-sel> := [ -O <sel_oem> ]
<options-sol> := [ -e <sol_escape_char> ]
This program lets you manage Intelligent Platform Management Interface (IPMI)
functions of either the local system, via a kernel device driver, or a remote
system, using IPMI v1.5 and IPMI v2.0. These functions include printing FRU
information, LAN configuration, sensor readings, and remote chassis power
control.
IPMI management of a local system interface requires a compatible
IPMI kernel driver to be installed and configured. On Linux this driver is
called OpenIPMI and it is included in standard distributions. On
Solaris this driver is called BMC and is included in Solaris 10.
Management of a remote station requires the IPMI-over-LAN interface to be
enabled and configured. Depending on the particular requirements of each
system it may be possible to enable the LAN interface using ipmitool over
the system interface.
- -a
- Prompt for the remote server password.
- -A <authtype>
- Specify an authentication type to use during IPMIv1.5 lan session
activation. Supported types are NONE, PASSWORD, MD2, MD5, or OEM.
- -b <channel>
- Set destination channel for bridged request.
- -B <channel>
- Set transit channel for bridged request (dual bridge).
- -b <channel>
- Set destination channel for bridged request.
- -B <channel>
- Set transit channel for bridged request. (dual bridge)
- -c
- Present output in CSV (comma separated variable) format. This is not
available with all commands.
- -C <ciphersuite>
- The remote server authentication, integrity, and encryption algorithms to
use for IPMIv2.0 lanplus connections. See table 22-19 in the
IPMIv2.0 specification. The default is 3 which specifies RAKP-HMAC-SHA1
authentication, HMAC-SHA1-96 integrity, and AES-CBC-128 encryption
algorithms.
- -d N
- Use device number N to specify the /dev/ipmiN (or /dev/ipmi/N or
/dev/ipmidev/N) device to use for in-band BMC communication. Used to
target a specific BMC on a multi-node, multi-BMC system through the ipmi
device driver interface. Default is 0.
- -e <sol_escape_char>
- Use supplied character for SOL session escape character. The default is to
use ~ but this can conflict with ssh sessions.
- -E
- The remote server password is specified by the environment variable
IPMI_PASSWORD or IPMITOOL_PASSWORD. The
IPMITOOL_PASSWORD takes precedence.
- -f <password_file>
- Specifies a file containing the remote server password. If this option is
absent, or if password_file is empty, the password will default to
NULL.
- -g
- Deprecated. Use: -o intelplus
- -h
- Get basic usage help from the command line.
- -H <address>
- Remote server address, can be IP address or hostname. This option is
required for lan and lanplus interfaces.
- -I <interface>
- Selects IPMI interface to use. Supported interfaces that are compiled in
are visible in the usage help output.
- -k <key>
- Use supplied Kg key for IPMIv2.0 authentication. The default is not to use
any Kg key.
- -K
- Read Kg key from IPMI_KGKEY environment variable.
- -l <lun>
- Set destination lun for raw commands.
- -L <privlvl>
- Force session privilege level. Can be CALLBACK, USER, OPERATOR,
ADMINISTRATOR. Default is ADMINISTRATOR. This value is ignored and always
set to ADMINISTRATOR when combined with -t target address.
- -m <local_address>
- Set the local IPMB address. The local address defaults to 0x20 or is auto
discovered on PICMG platforms when -m is not specified. There should be no
need to change the local address for normal operation.
- -N <sec>
- Specify nr. of seconds between retransmissions of lan/lanplus messages.
Defaults are 2 seconds for lan and 1 second for lanplus interfaces.
Command raw uses fixed value of 15 seconds. Command sol uses
fixed value of 1 second.
- -o <oemtype>
- Select OEM type to support. This usually involves minor hacks in place in
the code to work around quirks in various BMCs from various manufacturers.
Use -o list to see a list of current supported OEM types.
- -O <sel oem>
- Open selected file and read OEM SEL event descriptions to be used during
SEL listings. See examples in contrib dir for file format.
- -p <port>
- Remote server UDP port to connect to. Default is 623.
- -P <password>
- Remote server password is specified on the command line. If supported it
will be obscured in the process list. Note! Specifying the password
as a command line option is not recommended.
- -R <count>
- Set the number of retries for lan/lanplus interface (default=4). Command
raw uses fixed value of one try (no retries). Command hpm
uses fixed value of 10 retries.
- -s
- Deprecated. Use: -o supermicro
- -S <sdr_cache_file>
- Use local file for remote SDR cache. Using a local SDR cache can
drastically increase performance for commands that require knowledge of
the entire SDR to perform their function. Local SDR cache from a remote
system can be created with the sdr dump command.
- -t <target_address>
- Bridge IPMI requests to the remote target address. Default is 32. The
-L privlvl option is always ignored and value set to
ADMINISTRATOR.
- -T <address>
- Set transit address for bridge request (dual bridge).
- -T <transmit_address>
- Set transit address for bridge request. (dual bridge)
- -U <username>
- Remote server username, default is NULL user.
- -v
- Increase verbose output level. This option may be specified multiple times
to increase the level of debug output. If given three times you will get
hexdumps of all incoming and outgoing packets. Using it five times
provides details on request and expected reply procesing. The hpm
commands targetcap compprop abort upgstatus
rollback rollbackstatus selftestresult increases the
verbosity level
- -V
- Display version information.
- -y <hex key>
- Use supplied Kg key for IPMIv2.0 authentication. The key is expected in
hexadecimal format and can be used to specify keys with non-printable
characters. E.g. '-k PASSWORD' and '-y 50415353574F5244' are equivalent.
The default is not to use any Kg key.
- -Y
- Prompt for the Kg key for IPMIv2.0 authentication.
- -z <size>
- Change Size of Communication Channel. (OEM)
If no password method is specified then ipmitool will prompt the
user for a password. If no password is entered at the prompt, the remote
server password will default to NULL.
There are several security issues be be considered before enabling the IPMI LAN
interface. A remote station has the ability to control a system's power state
as well as being able to gather certain platform information. To reduce
vulnerability it is strongly advised that the IPMI LAN interface only be
enabled in 'trusted' environments where system security is not an issue or
where there is a dedicated secure 'management network'.
Further it is strongly advised that you should not enable IPMI for
remote access without setting a password, and that that password should not
be the same as any other password on that system.
When an IPMI password is changed on a remote machine with the
IPMIv1.5 lan interface the new password is sent across the network as
clear text. This could be observed and then used to attack the remote
system. It is thus recommended that IPMI password management only be done
over IPMIv2.0 lanplus interface or the system interface on the local
station.
For IPMI v1.5, the maximum password length is 16 characters.
Passwords longer than 16 characters will be truncated.
For IPMI v2.0, the maximum password length is 20 characters;
longer passwords are truncated.
- help
- This can be used to get command-line help on ipmitool commands. It may
also be placed at the end of commands to get option usage help.
ipmitool help
Commands:
bmc Deprecated. Use mc
channel Configure Management Controller channels
chassis Get chassis status and set power state
dcmi Data Center Management Interface
delloem Manage Dell OEM Extensions.
echo Used to echo lines to stdout in scripts
ekanalyzer run FRU-Ekeying analyzer using FRU files
event Send events to MC
exec Run list of commands from file
firewall Configure Firmware Firewall
fru Print built-in FRU and scan for FRU locators
fwum Update IPMC using Kontron OEM Firmware Update Manager
gendev Read/Write Device associated with Generic Device locators sdr
hpm Update HPM components using PICMG HPM.1 file
i2c Send an I2C Master Write-Read command and print response
ime Upgrade/Query Intel ME firmware
isol Configure and connect Intel IPMIv1.5 Serial-over-LAN
kontronoem Manage Kontron OEM Extensions
lan Configure LAN Channels
mc Management Controller status and global enables
nm Node Manager
pef Configure Platform Event Filtering (PEF)
picmg Run a PICMG/ATA extended command
power Shortcut to chassis power commands
raw Send a RAW IPMI request and print response
sdr Print Sensor Data Repository entries and readings
sel Print System Event Log (SEL)
sensor Print detailed sensor information
session Print session information
set Set runtime variable for shell and exec
shell Launch interactive IPMI shell
sol Configure and connect IPMIv2.0 Serial-over-LAN
spd Print SPD info from remote I2C device
sunoem Manage Sun OEM Extensions
tsol Configure and connect Tyan IPMIv1.5 Serial-over-LAN
user Configure Management Controller users
- channel
- authcap <channel number> <max priv>
-
Displays information about the authentication capabilities of
the selected channel at the specified privilege level.
- Possible privilege levels are:
-
1 Callback level
2 User level
3 Operator level
4 Administrator level
5 OEM Proprietary level
15 No access
- info [channel number]
-
Displays information about the selected channel. If no channel
is given it will display information about the currently used
channel.
> ipmitool channel info
Channel 0xf info:
Channel Medium Type : System Interface
Channel Protocol Type : KCS
Session Support : session-less
Active Session Count : 0
Protocol Vendor ID : 7154
- getaccess <channel number>
[<userid>]
Configure the given userid as the default on the given channel
number. When the given channel is subsequently used, the user is identified
implicitly by the given userid.
- setaccess <channel number> <userid>
[<callin=on|off>]
- [<ipmi=on|off>]
[<link=on|off>]
[<privilege=level>]
Configure user access information on the given channel for the
given userid.
- getciphers <ipmi|sol>
[<channel>]
-
Displays the list of cipher suites supported for the given
application (ipmi or sol) on the given channel.
- chassis
- status
-
Status information related to power, buttons, cooling, drives
and faults.
- power
- status
- on
- off
- cycle
- reset
- diag
- soft
- identify [<seconds>|force]
-
Identify interval.
Default is 15 seconds.
0 - Off
force - To turn on indefinitely
- policy
-
What to do when power is restored.
- list
-
Show available options.
- always-on
- previous
- always-off
- restart_cause
-
Last restart cause.
- poh
-
Get power on hours.
- bootdev
- none
-
Do not change boot device order.
- pxe
-
Force PXE boot.
- disk
-
Force boot from default Hard-drive.
- safe
-
Force boot from default Hard-drive, request Safe Mode.
- diag
-
Force boot from Diagnostic Partition.
- cdrom
-
Force boot from CD/DVD.
- bios
-
Force boot into BIOS Setup.
- floppy
-
Force boot from Floppy/primary removable media.
- bootparam
- force_pxe
-
Force PXE boot
- force_disk
-
Force boot from default Hard-drive
- force_safe
-
Force boot from default Hard-drive, request Safe Mode
- force_diag
-
Force boot from Diagnostic Partition
- force_cdrom
-
Force boot from CD/DVD
- force_bios
-
Force boot into BIOS Setup
- selftest
- dcmi
- discover
-
This command is used to discover supported capabilities in
DCMI.
- power <command>
-
Platform power limit command options are:
- reading
-
Get power related readings from the system.
- get_limit
-
Get the configured power limits.
- set_limit <parameter> <value>
-
Set a power limit option.
- Possible parameters/values are:
-
- action <No Action | Hard Power Off & Log Event to SEL |
Log Event to SEL>
-
Exception Actions are taken as "No Action",
"Hard Power Off system and log events to SEL", or "Log
event to SEL only".
- limit <number in Watts>
-
Power Limit Requested in Watts.
- correction <number in milliseconds>
-
Correction Time Limit in milliseconds.
- sample <number in seconds>
-
Statistics Sampling period in seconds.
- activate
-
Activate the set power limit.
- deactivate
-
Deactivate the set power limit.
- sensors
-
Prints the available DCMI sensors.
- asset_tag
-
Prints the platforms asset tag.
- set_asset_tag <string>
-
Sets the platforms asset tag
- get_mc_id_string
-
Get management controller identifier string.
- set_mc_id_string <string>
-
Set management controller identifier string. The maximum
length is 64 bytes including a null terminator.
- thermalpolicy [<get | set>]
-
Thermal Limit policy get/set.
- The commands are:
-
- Get <entityID> <instanceID>
-
Get Thermal Limit values.
entityID is the physical entity that a sensor or device
is associated with. instanceID is a particular instance of an
entity. Entity Instance can be in one of two ranges, system-relative or
device-relative. For example, a system with four processors could use an
Entity Instance value of "0" to identify the first
processor.
- Set <entityID> <instanceID>
-
Set Thermal Limit values.
entityID is the physical entity that a sensor or device
is associated with. instanceID is a particular instance of an
entity. Entity Instance can be in one of two ranges, system-relative or
device-relative. For example, a system with four processors could use an
Entity Instance value of "0" to identify the first
processor.
- get_temp_reading
-
Get Temperature Sensor Readings.
- get_conf_param
-
Get DCMI Configuration Parameters.
- set_conf_param <parameters>
-
Set DCMI Configuration Parameters.
- The Configuration Parameters are:
- activate_dhcp
-
Activate/restart DHCP
- dhcp_config
-
Discover DHCP Configuration.
- init
-
Set DHCP Initial timeout interval, in seconds. The recommended
default is four seconds.
- timeout
-
Set DHCP Server contact timeout interval, in seconds. The
recommended default timeout is two minutes.
- retry
-
Set DHCP Server contact retry interval, in seconds. The
recommended default timeout is sixty-four seconds.
- oob_discover
-
Ping/Pong Message for DCMI Discovery.
- delloem
The delloem commands provide information on Dell-specific
features.
- setled {b:d.f} {state..}
Sets the drive backplane LEDs for a device.
{b:d.f} = PCI Address of device (eg. 06:00.0)
{state} = one or more of the following:
online | present | hotspare | identify | rebuilding |
fault | predict | critical | failed
- lcd
set {mode}| {lcdqualifier}| {errordisplay}
Allows you to set the LCD mode and user-defined string.
- lcd set mode
{none}| {modelname}| {ipv4address}| {macaddress}|
{systemname}| {servicetag}| {ipv6address}|
{ambienttemp}| {systemwatt}| {assettag}|
{userdefined}<text>
Allows you to set the LCD display mode to any of the preceding
parameters.
- lcd set lcdqualifier
{watt}| {btuphr}|
{celsius}| {fahrenheit}
Allows you to set the unit for the system ambient temperature
mode.
- lcd set errordisplay
{sel}| {simple}
Allows you to set the error display.
- lcd info
Displays the LCD screen information.
- lcd set vkvm
{active}| {inactive}
Allows you to set the vKVM status to active or inactive. When it
is active and session is in progress, a message appears on LCD.
- lcd status
Displays the LCD status for vKVM display active or inactive and
Front Panel access mode (viewandmodify, view-only or disabled).
- mac
Displays the information about the system NICs.
- mac list
-
Displays the NIC MAC address and status of all NICs. It also
displays the DRAC/iDRAC MAC address.
- mac get
<NIC number>
Displays the selected NICs MAC address and status.
- lan
Displays the information of Lan.
- lan set
<Mode>
Sets the NIC selection mode (dedicated, shared with lom1, shared
with lom2,shared with lom3,shared with lom4,shared with failover lom1,shared
with failover lom2,shared with failover lom3,shared with failover
lom4,shared with Failover all loms, shared with Failover None).
- lan get
-
Returns the current NIC selection mode (dedicated, shared with
lom1, shared with lom2, shared with lom3, shared with lom4,shared with
failover lom1, shared with failover lom2,shared with failover
lom3,shared with failover lom4,shared with Failover all loms,shared with
Failover None).
- lan get active
-
Returns the current active NIC (dedicated, LOM1, LOM2, LOM3 or
LOM4).
- powermonitor
Displays power tracking statistics.
- powermonitor clear cumulativepower
Reset cumulative power reading.
- powermonitor clear peakpower
Reset peak power reading.
- powermonitor powerconsumption
<watt>|<btuphr>
Displays the power consumption in watt or btuphr.
- powermonitor powerconsumptionhistory
<watt>|<btuphr>
Displays the power consumption history in watt or btuphr.
- powermonitor getpowerbudget
<watt>|<btuphr>
Displays the power cap in watt or btuphr.
- powermonitor setpowerbudget
<val><watt|btuphr|percent>
Allows you to set the power cap in watt, BTU/hr or percentage.
- powermonitor enablepowercap
Enables set power cap.
- powermonitor disablepowercap
- vFlash info Card
Shows Extended SD Card information.
- echo
-
For echoing lines to stdout in scripts.
- ekanalyzer <command> <xx=filename1>
<xx=filename2> [<rc=filename3>] ...
NOTE : This command can support a maximum of 8 files per command line
filename1 : binary file that stores FRU data of a Carrier or an AMC
module
filename2 : binary file that stores FRU data of an AMC module.
These binary files can be generated from command:
ipmitool fru read <id> <filename>
filename3 : configuration file used for configuring On-Carrier Device ID
or OEM GUID. This file is optional.
xx : indicates the type of the file. It can take the following value:
oc : On-Carrier device
a1 : AMC slot A1
a2 : AMC slot A2
a3 : AMC slot A3
a4 : AMC slot A4
b1 : AMC slot B1
b2 : AMC slot B2
b3 : AMC slot B3
b4 : AMC slot B4
sm : Shelf Manager
The available commands for ekanalyzer are:
- print [<carrier | power | all>]
- carrier (default) <oc=filename1>
<oc=filename2> ...
-
Display point to point physical connectivity between carriers
and AMC modules.
Example:
> ipmitool ekanalyzer print carrier oc=fru oc=carrierfru
From Carrier file: fru
Number of AMC bays supported by Carrier: 2
AMC slot B1 topology:
Port 0 =====> On Carrier Device ID 0, Port 16
Port 1 =====> On Carrier Device ID 0, Port 12
Port 2 =====> AMC slot B2, Port 2
AMC slot B2 topology:
Port 0 =====> On Carrier Device ID 0, Port 3
Port 2 =====> AMC slot B1, Port 2
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
From Carrier file: carrierfru
On Carrier Device ID 0 topology:
Port 0 =====> AMC slot B1, Port 4
Port 1 =====> AMC slot B1, Port 5
Port 2 =====> AMC slot B2, Port 6
Port 3 =====> AMC slot B2, Port 7
AMC slot B1 topology:
Port 0 =====> AMC slot B2, Port 0
AMC slot B1 topology:
Port 1 =====> AMC slot B2, Port 1
Number of AMC bays supported by Carrier: 2
- power <xx=filename1> <xx=filename2>
...
-
Display power supply information between carrier and AMC
modules.
- all <xx=filename> <xx=filename>
...
-
Display both physical connectivity and power supply of each
carrier and AMC modules.
- frushow <xx=filename>
-
Convert a binary FRU file into human readable text format. Use -v option to
get more display information.
- summary [<match | unmatch | all>]
- match (default) <xx=filename>
<xx=filename> ...
-
Display only matched results of Ekeying match between an On-Carrier device
and an AMC module or between 2 AMC modules. Example:
> ipmitool ekanalyzer summary match oc=fru b1=amcB1 a2=amcA2
On-Carrier Device vs AMC slot B1
AMC slot B1 port 0 ==> On-Carrier Device 0 port 16
Matching Result
- From On-Carrier Device ID 0
-Channel ID 11 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot B1
-Channel ID 0 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
AMC slot B1 port 1 ==> On-Carrier Device 0 port 12
Matching Result
- From On-Carrier Device ID 0
-Channel ID 6 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot B1
-Channel ID 1 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
On-Carrier Device vs AMC slot A2
AMC slot A2 port 0 ==> On-Carrier Device 0 port 3
Matching Result
- From On-Carrier Device ID 0
-Channel ID 9 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot A2
-Channel ID 0 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
AMC slot B1 vs AMC slot A2
AMC slot A2 port 2 ==> AMC slot B1 port 2
Matching Result
- From AMC slot B1
-Channel ID 2 || Lane 0: enable
-Link Type: AMC.3 Storage
-Link Type extension: Serial Attached SCSI (SAS/SATA)
-Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
- To AMC slot A2
-Channel ID 2 || Lane 0: enable
-Link Type: AMC.3 Storage
-Link Type extension: Serial Attached SCSI (SAS/SATA)
-Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
- unmatch <xx=filename> <xx=filename>
...
-
Display the unmatched results of Ekeying match between an
On-Carrier device and an AMC module or between 2 AMC modules
- all <xx=filename> <xx=filename>
...
-
Display both matched result and unmatched results of Ekeying
match between two cards or two modules.
- event
- <predefined event number N>
-
Send a pre-defined test event to the System Event Log. The
following events are included as a means to test the functionality of
the System Event Log component of the BMC (an entry will be added each
time the event N command is executed).
Currently supported values for N are:
1 Temperature: Upper Critical: Going High
2 Voltage Threshold: Lower Critical: Going Low
3 Memory: Correctable ECC
NOTE: These pre-defined events will likely not produce
"accurate" SEL records for a particular system because they
will not be correctly tied to a valid sensor number, but they are
sufficient to verify correct operation of the SEL.
- file <filename>
-
Event log records specified in <filename> will be
added to the System Event Log.
The format of each line in the file is as follows:
<{EvM Revision} {Sensor Type} {Sensor
Num} {Event Dir/Type} {Event Data 0} {Event Data
1} {Event Data 2}>[# COMMENT]
e.g.: 0x4 0x2 0x60 0x1 0x52 0x0 0x0 # Voltage threshold: Lower
Critical: Going Low
EvM Revision - The "Event Message Revision"
is 0x04 for messages that comply with the IPMI 2.0 Specification and
0x03 for messages that comply with the IPMI 1.0 Specification.
Sensor Type - Indicates the Event Type or Class.
Sensor Num - Represents the 'sensor' within the
management controller that generated the Event Message.
Event Dir/Type - This field is encoded with the event
direction as the high bit (bit 7) and the event type as the low 7 bits.
Event direction is 0 for an assertion event and 1 for a deassertion
event.
See the IPMI 2.0 specification for further details on the
definitions for each field.
- <sensorid> <list>
-
Get a list of all the possible Sensor States and pre-defined
Sensor State Shortcuts available for a particular sensor.
sensorid is the character string representation of the sensor and
must be enclosed in double quotes if it includes white space. Several
different commands including ipmitool sensor list may be used to
obtain a list that includes the sensorid strings representing the
sensors on a given system.
> ipmitool -I open event "PS 2T Fan Fault" list
Finding sensor PS 2T Fan Fault... ok
Sensor States:
State Deasserted
State Asserted
Sensor State Shortcuts:
present absent
assert deassert
limit nolimit
fail nofail
yes no
on off
up down
- <sensorid> <sensor state>
[<direction>]
-
Generate a custom event based on existing sensor information.
The optional event direction can be either assert
(the default) or deassert.
> ipmitool event "PS 2T Fan Fault" "State
Asserted"
Finding sensor PS 2T Fan Fault... ok
0 | Pre-Init Time-stamp | Fan PS 2T Fan Fault | State Asserted
> ipmitool event "PS 2T Fan Fault" "State
Deasserted"
Finding sensor PS 2T Fan Fault... ok
0 | Pre-Init Time-stamp | Fan PS 2T Fan Fault | State Desserted
- exec <filename>
-
Execute ipmitool commands from filename. Each line
is a complete command. The syntax of the commands are defined by the COMMANDS
section in this manpage. Each line may have an optional comment at the end of
the line, delimited with a `#' symbol.
e.g., a command file with two lines:
sdr list # get a list of sdr records
sel list # get a list of sel records
- firewall
-
This command supports the Firmware Firewall capability. It may
be used to add or remove security-based restrictions on certain
commands/command sub-functions or to list the current firmware firewall
restrictions set on any commands. For each firmware firewall command
listed below, parameters may be included to cause the command to be
executed with increasing granularity on a specific LUN, for a specific
NetFn, for a specific IPMI Command, and finally for a specific command's
sub-function (see Appendix H in the IPMI 2.0 Specification for a listing
of any sub-function numbers that may be associated with a particular
command).
Parameter syntax and dependencies are as follows:
[<channel H>] [<lun L>
[ <netfn N> [<command C
[<subfn S>]]]]
Note that if "netfn <N>" is specified,
then "lun <L>" must also be specified; if
"command <C>" is specified, then "netfn
<N>" (and therefore "lun <L>")
must also be specified, and so forth.
"channel <H>" is an optional and
standalone parameter. If not specified, the requested operation will be
performed on the current channel. Note that command support may vary
from channel to channel.
Firmware firewall commands:
- info [<Parms as described above>]
-
List firmware firewall information for the specified LUN,
NetFn, and Command (if supplied) on the current or specified channel.
Listed information includes the support, configurable, and enabled bits
for the specified command or commands.
Some usage examples:
- info [<channel H>] [<lun L>]
-
This command will list firmware firewall information for all
NetFns for the specified LUN on either the current or the specified
channel.
- info [<channel H>] [<lun L> [
<netfn N> ]
-
This command will print out all command information for a
single LUN/NetFn pair.
- info [<channel H>] [<lun L> [
<netfn N> [<command C] ]]
-
This prints out detailed, human-readable information showing
the support, configurable, and enabled bits for the specified command on
the specified LUN/NetFn pair. Information will be printed about each of
the command subfunctions.
- info [<channel H>] [<lun L> [
<netfn N> [<command C [<subfn
S>]]]]
-
Print out information for a specific sub-function.
- enable [<Parms as described above>]
-
This command is used to enable commands for a given NetFn/LUN
combination on the specified channel.
- disable [<Parms as described above>]
[force]
-
This command is used to disable commands for a given NetFn/LUN
combination on the specified channel. Great care should be taken if
using the "force" option so as not to disable the "Set
Command Enables" command.
- reset [<Parms as described above>]
-
This command may be used to reset the firmware firewall back
to a state where all commands and command sub-functions are enabled.
- fru
- print
-
Read all Field Replaceable Unit (FRU) inventory data and
extract such information as serial number, part number, asset tags, and
short strings describing the chassis, board, or product.
- read <fru id> <fru file>
-
fru id is the digit ID of the FRU (see output of 'fru
print'). fru file is the absolute pathname of a file in which to
dump the binary FRU data pertaining to the specified FRU entity.
- write <fru id> <fru file>
-
fru id is the digit ID of the FRU (see output of 'fru
print'). fru file is the absolute pathname of a file from which
to pull the binary FRU data before uploading it to the specified
FRU.
- upgEkey <fru id> <fru file>
-
Update a multirecord FRU location. fru id is the digit
ID of the FRU (see output of 'fru print'). fru file is the
absolute pathname of a file from which to pull the binary FRU data to
upload into the specified multirecord FRU entity.
- edit <fru id>
-
This command provides interactive editing of some supported
records, namely PICMG Carrier Activation Record. fru id is the
digit ID of the FRU (see output of 'fru print'); default is 0.
- edit <fru id> field <section>
<index> <string>
-
This command may be used to set a field string to a new value.
It replaces the FRU data found at index in the specified
section with the supplied string.
- fru id is the digit ID of the FRU (see output of 'fru print').
-
- <section> is a string which refers to FRU Inventory
Information
- Storage Areas and may be refer to:
- c FRU Inventory Chassis Info Area
-
- b FRU Inventory Board Info Area
-
- p FRU Inventory Product Info Area
-
- <index> specifies the field number. Field numbering starts on
the first 'english text' field type. For instance in the
<board> info area field '0' is <Board
Manufacturer> and field '2' is <Board Serial Number>;
see IPMI Platform Management FRU Information Storage Definition v1.0 R1.1
for field locations.
-
- <string> must be the same length as the string being replaced
and must be 8-bit ASCII (0xCx).
-
- edit <fru id> oem iana
<record> <format> [<args>]
-
This command edits the data found in the multirecord area.
Support for OEM specific records is limited.
- fwum
Update IPMC using Kontron OEM Firmware Update Manager.
- info
-
Show information about current firmware.
- status
-
Show status of each firmware bank present in the hardware.
- download <filename>
-
Download specified firmware.
- upgrade [filename]
-
Install firmware upgrade. If the filename is specified, the
file is downloaded first, otherwise the last firmware downloaded is
used.
- rollback
-
Ask IPMC to rollback to previous version.
- tracelog
-
Show firmware upgrade log.
- gendev
- list
-
List All Generic Device Locators.
- read <sdr name> <file>
-
Read to file eeprom specify by Generic Device Locators.
- write <sdr name> <file>
-
Write from file eeprom specify by Generic Device Locators
- hpm
PICMG HPM.1 Upgrade Agent
- check
-
Check the target information.
- check <filename>
-
Display both the existing target version and image version on the screen.
- download <filename>
-
Download specified firmware.
- upgrade <filename> [all] [component
<x>] [activate]
-
Upgrade the firmware using a valid HPM.1 image file. If no option is
specified, the firmware versions are checked first and the firmware is
upgraded only if they are different.
- all
-
Upgrade all components even if the firmware versions are the same (use this
only after using "check" command).
- component <x>
-
Upgrade only given component from the given file.
component 0 - BOOT
component 1 - RTK
- activate
-
Activate new firmware right away.
- activate
-
Activate the newly uploaded firmware.
- targetcap
-
Get the target upgrade capabilities.
- compprop <id> <select>
-
Get the specified component properties. Valid component id: 0-7.
Select can be one of following:
0 - General properties
1 - Current firmware version
2 - Description string
3 - Rollback firmware version
4 - Deferred firmware version
- abort
-
Abort the on-going firmware upgrade.
- upgstatus
-
Show status of the last long duration command.
- rollback
-
Perform manual rollback on the IPM Controller firmware.
- rollbackstatus
-
Show the rollback status.
- selftestresult
-
Query the self test results.
- i2c <i2caddr> <read bytes> [<write
data>]
-
This command may be used to execute raw I2C commands with the
Master Write-Read IPMI command.
- ime
- help
-
Print usage information
- info
-
Displays information about the Manageability Engine (ME)
- update <file>
-
Upgrade the ME firmware with the specified image file
WARNING You MUST use a supported image provided by your board
vendor
- rollback
-
Perform manual rollback of the ME firmware
- isol
- info
-
Retrieve information about the Intel IPMI v1.5 Serial-Over-LAN
configuration.
- set <parameter> <value>
-
Configure parameters for Intel IPMI v1.5 Serial-over-LAN.
- Valid parameters and values are:
-
- enabled
- true, false.
- privilege-level
- user, operator, admin, oem.
- bit-rate
- 9.6, 19.2, 38.4, 57.6, 115.2.
- activate
-
Causes ipmitool to enter Intel IPMI v1.5 Serial Over LAN mode.
An RMCP+ connection is made to the BMC, the terminal is set to raw mode,
and user input is sent to the serial console on the remote server. On
exit, the SOL payload mode is deactivated and the terminal is reset to
its original settings.
Special escape sequences are provided to control the SOL
session:
- ~. Terminate connection
- ~^Z Suspend ipmitool
- ~^X Suspend ipmitool, but don't restore tty on restart
- ~B Send break
- ~~ Send the escape character by typing it twice
- ~? Print the supported escape sequences
Note that escapes are only recognized immediately after
newline.
- kontronoem
OEM commands specific to Kontron devices.
- setsn
-
Set FRU serial number.
- setmfgdate
-
Set FRU manufacturing date.
- nextboot <boot device>
-
Select the next boot order on the Kontron CP6012.
- lan
These commands will allow you to configure IPMI LAN channels with
network information so they can be used with the ipmitool lan and
lanplus interfaces. NOTE: To determine on which channel the
LAN interface is located, issue the `channel info number' command
until you come across a valid 802.3 LAN channel. For example:
> ipmitool -I open channel info 1
Channel 0x1 info:
Channel Medium Type : 802.3 LAN
Channel Protocol Type : IPMB-1.0
Session Support : session-based
Active Session Count : 8
Protocol Vendor ID : 7154
- print [<channel>]
-
Print the current configuration for the given channel. The
default will print information on the first found LAN channel.
- set <channel number> <command>
<parameter>
-
Set the given command and parameter on the specified channel.
Valid command/parameter options are:
- ipaddr <x.x.x.x>
-
Set the IP address for this channel.
- netmask <x.x.x.x>
-
Set the netmask for this channel.
- macaddr <xx:xx:xx:xx:xx:xx>
-
Set the MAC address for this channel.
- defgw ipaddr <x.x.x.x>
-
Set the default gateway IP address.
- defgw macaddr <xx:xx:xx:xx:xx:xx>
-
Set the default gateway MAC address.
- bakgw ipaddr <x.x.x.x>
-
Set the backup gateway IP address.
- bakgw macaddr <xx:xx:xx:xx:xx:xx>
-
Set the backup gateway MAC address.
- password <pass>
-
Set the null user password.
- snmp <community string>
-
Set the SNMP community string.
- user
-
Enable user access mode for userid 1 (issue the `user' command
to display information about userids for a given channel).
- access <on|off>
-
Set LAN channel access mode.
- alert <on|off>
-
Enable or disable PEF alerting for this channel.
- ipsrc <source>
-
Set the IP address source:
none unspecified
static manually configured static IP address
dhcp address obtained by BMC running DHCP
bios address loaded by BIOS or system software
- arp respond <on|off>
-
Set BMC generated ARP responses.
- arp generate <on|off>
-
Set BMC generated gratuitous ARPs.
- arp interval <seconds>
-
Set BMC generated gratuitous ARP interval.
- vlan id <off|id>
-
Disable VLAN operation or enable VLAN and set the ID.
ID: value of the virtual lan identifier between 1 and 4094 inclusive.
- vlan priority <priority>
-
Set the priority associated with VLAN frames.
ID: priority of the virtual lan frames between 0 and 7 inclusive.
- auth <level,...>
<type,...>
-
Set the valid authtypes for a given auth level.
Levels: callback, user, operator, admin
Types: none, md2, md5, password, oem
- cipher_privs <privlist>
-
Correlates cipher suite numbers with the maximum privilege
level that is allowed to use it. In this way, cipher suites can
restricted to users with a given privilege level, so that, for example,
administrators are required to use a stronger cipher suite than normal
users.
The format of privlist is as follows. Each character
represents a privilege level and the character position identifies the
cipher suite number. For example, the first character represents cipher
suite 0, the second represents cipher suite 1, and so on.
privlist must be 15 characters in length.
Characters used in privlist and their associated
privilege levels are:
X Cipher Suite Unused
c CALLBACK
u USER
o OPERATOR
a ADMIN
O OEM
So, to set the maximum privilege for cipher suite 0 to USER
and suite 1 to ADMIN, issue the following command:
> ipmitool -I interface lan set channel
cipher_privs uaXXXXXXXXXXXXX
- bad_pass_thresh <thresh_num> <1|0>
<reset_interval> <lockout_interval>
-
Sets the Bad Password Threshold.
<thresh_num> If non-zero, this value determines
the number of sequential bad passwords that will be allowed to be
entered for the identified user before the user is automatically
disabled from access on the channel.
<1|0> 1 = generate a Session Audit sensor
"Invalid password disable" event message. 0 = do not generate
an event message when the user is disabled.
<reset_interval> Attempt Count Reset Interval.
The interval, in tens of seconds, for which the accumulated count of bad
password attempts is retained before being automatically reset to
zero.
<lockout_interval> User Lockout Interval. The
interval, in tens of seconds, that the user will remain disabled after
being disabled because the Bad Password Threshold number was
reached.
- alert print [<channel>] [<alert
destination>]
-
Print alert information for the specified channel and
destination. The default will print all alerts for all alert
destinations on the first found LAN channel.
- alert set <channel number> <alert
destination> <command> <parameter>
-
Set an alert on the given LAN channel and destination. Alert
Destinations are listed via the 'lan alert print' command. Valid
command/parameter options are:
- ipaddr <x.x.x.x>
-
Set alert IP address.
- macaddr <xx:xx:xx:xx:xx:xx>
-
Set alert MAC address.
- gateway <default | backup>
-
Set the channel gateway to use for alerts.
- ack <on | off>
-
Set Alert Acknowledge on or off.
- type <pet | oem1 | oem2>
-
Set the destination type as PET or OEM.
- time <seconds>
-
Set ack timeout or unack retry interval.
- retry <number>
-
Set the number of alert retries.
- stats get [<channel number>]
-
Retrieve information about the IP connections on the specified
channel. The default will retrieve statistics on the first found LAN
channel.
- stats clear [<channel number>]
-
Clear all IP/UDP/RMCP Statistics to 0 on the specified
channel. The default will clear statistics on the first found LAN
channel.
- mc | bmc
- reset <warm|cold>
-
Instructs the BMC to perform a warm or cold reset.
- guid
-
Display the Management Controller Globally Unique
IDentifier.
- info
-
Displays information about the BMC hardware, including device
revision, firmware revision, IPMI version supported, manufacturer ID,
and information on additional device support.
- watchdog
-
These commands allow a user to view and change the current
state of the watchdog timer.
- get
-
Show current Watchdog Timer settings and countdown state.
- reset
-
Reset the Watchdog Timer to its most recent state and restart
the countdown timer.
- off
-
Turn off a currently running Watchdog countdown timer.
- selftest
-
Check on the basic health of the BMC by executing the Get Self
Test results command and report the results.
- getenables
-
Displays a list of the currently enabled options for the BMC.
- setenables <option>=[on|off]
-
Enables or disables the given option. This command is
only supported over the system interface according to the IPMI
specification. Currently supported values for option include:
- recv_msg_intr
-
Receive Message Queue Interrupt
- event_msg_intr
-
Event Message Buffer Full Interrupt
- event_msg
-
Event Message Buffer
- system_event_log
-
System Event Logging
- oem0
-
OEM-Defined option #0
- oem1
-
OEM-Defined option #1
- oem2
-
OEM-Defined option #2
- getsysinfo <argument>
- Retrieves system info from bmc for given argument.
See setsysinfo for argument definitions
- setsysinfo <argument> <string>
- Stores system info string to bmc for given argument
- Possible arguments are:
- primary_os_name Primary Operating System Name
- os_name Operating System Name
- system_name System Name of Server
- delloem_os_version Running version of operating system
- delloem_URL URL of BMC Webserver
- chassis
- status
-
Displays information regarding the high-level status of the
system chassis and main power subsystem.
- poh
-
This command will return the Power-On Hours counter.
- identify <interval>
-
Control the front panel identify light. Default interval is 15
seconds. Use 0 to turn off. Use "force" to turn on
indefinitely.
- restart_cause
-
Query the chassis for the cause of the last system
restart.
- selftest
-
Check on the basic health of the BMC by executing the Get Self
Test results command and report the results.
- policy
-
Set the chassis power policy in the event power failure.
- list
-
Return supported policies.
- always-on
-
Turn on when power is restored.
- previous
-
Returned to previous state when power is restored.
- always-off
-
Stay off after power is restored.
- power
-
Performs a chassis control command to view and change the
power state.
- status
-
Show current chassis power status.
- on
-
Power up chassis.
- off
-
Power down chassis into soft off (S4/S5 state).
WARNING: This command does not initiate a clean shutdown of the
operating system prior to powering down the system.
- cycle
-
Provides a power off interval of at least 1 second. No action
should occur if chassis power is in S4/S5 state, but it is recommended
to check power state first and only issue a power cycle command if the
system power is on or in lower sleep state than S4/S5.
- reset
-
This command will perform a hard reset.
- diag
-
Pulse a diagnostic interrupt (NMI) directly to the
processor(s).
- soft
-
Initiate a soft-shutdown of OS via ACPI. This can be done in a
number of ways, commonly by simulating an overtemperture or by
simulating a power button press. It is necessary for there to be
Operating System support for ACPI and some sort of daemon watching for
events for this soft power to work.
- bootdev <device>
[<clear-cmos=yes|no>]
[<options=help,...>]
-
Request the system to boot from an alternate boot device on
next reboot. The clear-cmos option, if supplied, will instruct
the BIOS to clear its CMOS on the next reboot. Various options may be
used to modify the boot device settings. Run "bootdev none
options=help" for a list of available boot device
modifiers/options.
- Currently supported values for <device> are:
- none
-
Do not change boot device
- pxe
-
Force PXE boot
- disk
-
Force boot from BIOS default boot device
- safe
-
Force boot from BIOS default boot device, request Safe
Mode
- diag
-
Force boot from diagnostic partition
- cdrom
-
Force boot from CD/DVD
- bios
-
Force boot into BIOS setup
- floppy
-
Force boot from Floppy/primary removable media
- bootparam
-
Get or set various system boot option parameters.
- get <param #>
-
Get boot parameter. Currently supported values for
<param #> are:
0 - Set In Progress
1 - Service Partition Selector
2 - Service Partition Scan
3 - BMC Boot Flag Valid Bit Clearing
4 - Boot Info Acknowledge
5 - Boot Flags
6 - Boot Initiator Info
7 - Boot Initiator Mailbox
- set <device>
[<options=help,...>]
-
Set boot device parameter used for next boot. Various options
may be used to change when the the next boot device is cleared. Run
"options=help" for a list of available bootparam set
device options.
- Currently supported bootparam device settings are:
- force_pxe
-
Force PXE boot
- force_disk
-
Force boot from default hard-drive
- force_safe
-
Force boot from default hard-drive, request Safe Mode
- force_diag
-
Force boot from diagnostic partition
- force_cdrom
-
Force boot from CD/DVD
- force_bios
-
Force boot into BIOS setup
- Currently supported bootparam options settings are associated with
BMC Boot Valid Bit Clearing and are as follows: Any option can be prefixed
with "no-" to invert the sense of the operation.
- PEF
-
Clear valid bit on reset/power cycle caused by PEF
- timeout
-
Automatically clear boot flag valid bit if Chassis Control
command is not received within 60 seconds.
- watchdog
-
Clear valid bit on reset/power cycle caused by watchdog
timeout
- reset
-
Clear valid bit on push button reset / soft-reset
- power
-
Clear valid bit on power up via power push button or wake
event
- nm
- alert
- clear dest <dest>
-
Clear the Node Manager Alert lan destination.
- get
-
Get the Node Manager Alert settings.
- set chan <chan> dest <dest>
string <string>
-
Set the Node Manager alert channel, lan destination, and alert
string number.
- capability
-
Obtain the Node Manager power control capabilities and
ranges.
- control
- enable|disable
- global
-
Enable/disable all policies for all domains.
- per_domain <platform|CPU|Memory>
-
Enable/disable all policies of the specified domain.
- per_policy <0-7>
-
Enable/disable the policy for the specified domain/policy
combination.
- discover
-
Discover Node Manager presence as well as the Node Manager
version, revision, and patch number.
- policy
- add
- power <watts> policy_id <0-7> [correction
auto|soft|hard] trig_lim <seconds> stats <seconds>
[domain <platform|CPU|Memory>]
enable|disable
-
Add a new power policy, or overwrite an existing policy. The
correction parameter is the agressiveness of frequency limiting,
default is auto. The trig_lim is the correction time limit and
must be at least 6000 and not greater than 65535. The stats
setting is the averaging period in seconds and ranges from 1-65535. If
domain is not supplied a default of platform is used.
- inlet <temp> policy_id <0-7> [correction
auto|soft|hard] trig_lim <seconds> stats <seconds>
[domain <platform|CPU|Memory>]
enable|disable
-
Add a new inlet temp policy, or overwrite an existing policy.
The correction parameter is the agressiveness of frequency
limiting, default is auto. The trig_lim is the correction time
limit and must be at least 6000 and not greater than 65535. The
stats setting is the averaging period in seconds and ranges from
1-65535. If domain is not supplied a default of platform is used.
- get policy_id <0-7>
-
Get a previously stored policy.
- limiting
-
Report policy number if any policy is limiting power.
- remove policy_id <0-7> [domain
<platform|CPU|Memory>]
-
Remove a policy. If domain is not supplied a default of
platform is used.
- power min <minimum> max <maximum>
[domain <platform|CPU|Memory>]
-
Configure Node Manager power minimum and maximum power draw
limits. The min and max values must be in the range of
0-65535. If domain is not supplied a default of platform is used.
- reset
- comm policy_id <0-7> [domain
<platform|CPU|Memory>]
-
Reset Node Manager communication statistics. If domain is not
supplied a default of platform is used.
- global
-
Reset Node Manager global statistics.
- memory policy_id <0-7> [domain
<platform|CPU|Memory>]
-
Reset Node Manager memory throttling statistics. If domain is
not supplied a default of platform is used.
- per_policy policy_id <0-7> [domain
<platform|CPU|Memory>]
-
Reset Node Manager per policy statistics. If domain is not
supplied a default of platform is used.
- requests policy_id <0-7> [domain
<platform|CPU|Memory>]
-
Reset Node Manager unhandled requests statistics. If domain is
not supplied a default of platform is used.
- response policy_id <0-7> [domain
<platform|CPU|Memory>]
-
Reset Node Manager response time statistics. If domain is not
supplied a default of platform is used.
- throttling policy_id <0-7> [domain
<platform|CPU|Memory>]
-
Reset Node Manager throttling statistics. If domain is not
supplied a default of platform is used.
- statistics
- comm_fail
-
Report Node Manager communication failure statistics.
- cpu_throttling
-
Report Node Manager cpu throttling statistics.
- mem_throttling
-
Report Node Manager memory throttling statistics.
- policy_power policy_id <0-7> [domain
<platform|CPU|Memory>]
-
Report Node Manager per policy power statistics (policy must
be a power limit type policy). If domain is not supplied a default of
platform is used.
- policy_temps policy_id <0-7> [domain
<platform|CPU|Memory>]
-
Report Node Manager per policy temp statistics (policy must be
an inlet temp limit policy). If domain is not supplied a default of
platform is used.
- policy_throt policy_id <0-7> [domain
<platform|CPU|Memory>]
-
Report Node Manager per policy throttling statistics. If
domain is not supplied a default of platform is used.
- requests
-
Report Node Manager unhandled requests statistics.
- response
-
Report Node Manager response time statistics.
- suspend
- get policy_id <0-7> [domain
<platform|CPU|Memory>]
-
Get Node Manager policy suspend periods. If domain is not
supplied a default of platform is used.
- set policy_id <0-7> [domain
<platform|CPU|Memory>] <start> <stop> <repeat>
-
Set Node Manager policy suspend periods. If domain is not
supplied a default of platform is used. The <start> and
<stop> values must be in the range of 0-239, which is the number
of minutes past midnight divided by 6. The <repeat> value is the
daily recurrence pattern. Bit 0 is repeat every Monday, bit 1 is repeat
every Tuesday, on through bit 6 for Sunday.
- threshold
- get policy_id <0-7> [domain
<platform|CPU|Memory>]
-
Get Node Manager policy Alert Threshold settings. If domain is
not supplied a default of platform is used.
- set policy_id <0-7> [domain
<platform|CPU|Memory>] thresh_array
-
Set Node Manager policy Alert Threshold values. If domain is
not supplied a default of platform is used. The thresh_array is
1, 2, or 3 integers that set three alert threshold settings. The setting
type is a power or temperature value which must match the type of
policy.
- pef
- info
-
This command will query the BMC and print information about
the PEF supported features.
- status
-
This command prints the current PEF status (the last SEL entry
processed by the BMC, etc).
- policy
-
This command lists the PEF policy table entries. Each policy
entry describes an alert destination. A policy set is a collection of
table entries. PEF alert actions reference policy sets.
- list
-
This command lists the PEF table entries. Each PEF entry
relates a sensor event to an action. When PEF is active, each platform
event causes the BMC to scan this table for entries matching the event,
and possible actions to be taken. Actions are performed in priority
order (higher criticality first).
- picmg <properties>
Run a PICMG/ATA extended command. Get PICMG properties may be used
to obtain and print Extension major version information, PICMG identifier,
FRU Device ID and Max FRU Device ID.
- addrinfo
-
Get address information. This command may return information
on the Hardware address, IPMB-0 Address, FRU ID, Site/Entity ID, and
Site/Entity Type.
- frucontrol <fru id> <options>
-
Set various control options:
- 0x00 - Cold Reset
-
- 0x01 - Warm Reset
-
- 0x02 - Graceful Reboot
-
- 0x03 - Issue Diagnostic Interrupt
-
- 0x04 - Quiesce [AMC only]
-
- 0x05-0xFF - Cold Reset
-
- activate <fru id>
-
Activate the specified FRU.
- deactivate <fru id>
-
Deactivate the specified FRU.
- policy get <fru id>
-
Get FRU activation policy.
- policy set <fru id> <lockmask>
<lock>
-
Set FRU activation policy. lockmask is 1 or 0 to
indicate action on the deactivation or activation locked bit
respectively. lock is 1 or 0 to set/clear locked bit.
- portstate
set|getall|getgranted|getdenied
<parameters>
-
Get or set various port states. See usage for parameter details.
- power <chassis power command>
-
Shortcut to the chassis power commands. See the
chassis power commands for usage information.
- raw <netfn> <cmd>
[<data>]
-
This will allow you to execute raw IPMI commands. For example
to query the POH counter with a raw command:
> ipmitool -v raw 0x0 0xf
RAW REQ (netfn=0x0 cmd=0xf data_len=0)
RAW RSP (5 bytes)
3c 72 0c 00 00
Note that the OpenIPMI driver provided by the Linux
kernel will reject the Get Message, Send Message and Read Event Message
Buffer commands because it handles the message sequencing
internally.
- sdr
- get <id> ... [<id>]
-
Prints information for sensor data records specified by sensor
id.
- info
-
This command will query the BMC for Sensor Data Record (SDR)
Repository information.
- type [<sensor type>]
-
This command will display all records from the SDR Repository
of a specific type. Run with type list (or simply with no type)
to see the list of available types. For example to query for all
Temperature sensors:
> ipmitool sdr type Temperature
Baseboard Temp | 30h | ok | 7.1 | 28 degrees C
FntPnl Amb Temp | 32h | ok | 12.1 | 24 degrees C
Processor1 Temp | 98h | ok | 3.1 | 57 degrees C
Processor2 Temp | 99h | ok | 3.2 | 53 degrees C
- list | elist
[<all|full|compact|event|mcloc|fru|generic>]
-
This command will read the Sensor Data Records (SDR) and
extract sensor information of a given type, then query each sensor and
print its name, reading, and status. If invoked as elist then it
will also print sensor number, entity id and instance, and asserted
discrete states.
The default output will only display full and
compact sensor types, to see all sensors use the all type
with this command.
- Valid types are:
- all
-
All SDR records (Sensor and Locator)
- full
-
Full Sensor Record
- compact
-
Compact Sensor Record
- event
-
Event-Only Sensor Record
- mcloc
-
Management Controller Locator Record
- fru
-
FRU Locator Record
- generic
-
Generic SDR records
- entity <id>[.<instance>]
-
Displays all sensors associated with an entity. Get a list of
valid entity ids on the target system by issuing the sdr elist
command. A list of all entity ids can be found in the IPMI
specifications.
- dump <file>
-
Dumps raw SDR data to a file. This data file can then be used
as a local SDR cache of the remote managed system with the -S
<file> option on the ipmitool command line. This can greatly
improve performance over system interface or remote LAN.
- fill sensors
-
Create the SDR Repository for the current configuration. Will
perform a 'Clear SDR Repository' command so be careful.
- fill file <filename>
-
Fill the SDR Repository using records stored in a binary data
file. Will perform a 'Clear SDR Repository' command so be careful.
- sel
-
NOTE: System Event Log (SEL) entry-times are displayed as
`Pre-Init Time-stamp' if the SEL clock needs to be set. Ensure that the
SEL clock is accurate by invoking the sel time get and sel
time set <time string> commands.
- info
-
This command will query the BMC for information about the
System Event Log (SEL) and its contents.
- clear
-
This command will clear the contents of the SEL. It cannot be
undone so be careful.
- list | elist
-
When this command is invoked without arguments, the entire
contents of the System Event Log are displayed. If invoked as
elist (extended list) it will also use the Sensor Data Record
entries to display the sensor ID for the sensor that caused each event.
Note this can take a long time over the system interface.
- <count> | first <count>
-
Displays the first count (least-recent) entries in the
SEL. If count is zero, all entries are displayed.
- last <count>
-
Displays the last count (most-recent) entries in the
SEL. If count is zero, all entries are displayed.
- delete <SEL Record ID> ... <SEL Record
ID>
-
Delete one or more SEL event records.
- add <filename ID>
-
Read event entries from a file and add them to the SEL. New
SEL entries area added onto the SEL after the last record in the SEL.
Record added is of type 2 and is automatically timestamped.
- get <SEL Record ID>
-
Print information on the specified SEL Record entry.
- save <file>
-
Save SEL records to a text file that can be fed back into the
event file ipmitool command. This can be useful for testing Event
generation by building an appropriate Platform Event Message file based
on existing events. Please see the available help for the 'event file
...' command for a description of the format of this file.
- writeraw <file>
-
Save SEL records to a file in raw, binary format. This file
can be fed back to the sel readraw ipmitool command for
viewing.
- readraw <file>
-
Read and display SEL records from a binary file. Such a file
can be created using the sel writeraw ipmitool command.
- time
- get
-
Displays the SEL clock's current time.
- set <time string>
-
Sets the SEL clock. Future SEL entries will use the time set
by this command. <time string> is of the form
"MM/DD/YYYY HH:MM:SS". Note that hours are in 24-hour form. It
is recommended that the SEL be cleared before setting the time.
- sensor
- list
-
Lists sensors and thresholds in a wide table format.
- get <id> ... [<id>]
-
Prints information for sensors specified by name.
- thresh <id> <threshold>
<setting>
-
This allows you to set a particular sensor threshold value.
The sensor is specified by name.
- Valid thresholds are:
-
unr Upper Non-Recoverable
ucr Upper Critical
unc Upper Non-Critical
lnc Lower Non-Critical
lcr Lower Critical
lnr Lower Non-Recoverable
- thresh <id> lower <lnr>
<lcr> <lnc>
-
This allows you to set all lower thresholds for a sensor at
the same time. The sensor is specified by name and the thresholds are
listed in order of Lower Non-Recoverable, Lower Critical, and Lower
Non-Critical.
- thresh <id> upper <unc>
<ucr> <unr>
-
This allows you to set all upper thresholds for a sensor at
the same time. The sensor is specified by name and the thresholds are
listed in order of Upper Non-Critical, Upper Critical, and Upper
Non-Recoverable.
- session
- info <active|all|id 0xnnnnnnnn|handle
0xnn>
-
Get information about the specified session(s). You may
identify sessions by their id, by their handle number, by their active
status, or by using the keyword `all' to specify all sessions.
- set
- hostname <host>
-
Session hostname.
- username <user>
-
Session username.
- password <pass>
-
Session password.
- privlvl <level>
-
Session privilege level force.
- authtype <type>
-
Authentication type force.
- localaddr <addr>
-
Local IPMB address.
- targetaddr <addr>
-
Remote target IPMB address.
- port <port>
-
Remote RMCP port.
- csv [level]
-
Enable output in comma separated format. Affects following
commands: user, channel, isol, sunoem,
sol, sensor, sdr, sel, session.
- verbose [verbose]
-
Verbosity level.
- shell
This command will launch an interactive shell which you
can use to send multiple ipmitool commands to a BMC and see the responses.
This can be useful instead of running the full ipmitool command each time.
Some commands will make use of a Sensor Data Record cache and you will see
marked improvement in speed if these commands are able to reuse the same cache
in a shell session. LAN sessions will send a periodic keepalive command to
keep the IPMI session from timing out.
- sol
- info [<channel number>]
-
Retrieve information about the Serial-Over-LAN configuration
on the specified channel. If no channel is given, it will display SOL
configuration data for the currently used channel.
- payload <enable | disable | status>
<channel number> <userid>
-
Enable, disable or show status of SOL payload for the user on
the specified channel.
- set <parameter> <value>
[<channel>]
-
Configure parameters for Serial Over Lan. If no channel is
given, it will display SOL configuration data for the currently used
channel. Configuration parameter updates are automatically guarded with
the updates to the set-in-progress parameter.
- Valid parameters and values are:
-
- set-in-progress
- set-complete set-in-progress commit-write
- enabled
- true false
- force-encryption
- true false
- force-authentication
- true false
- privilege-level
- user operator admin oem
- character-accumulate-level
- Decimal number given in 5 milliseconds increments
- character-send-threshold
- Decimal number
- retry-count
- Decimal number. 0 indicates no retries after packet is transmitted.
- retry-interval
- Decimal number in 10 millisecond increments. 0 indicates that retries
should be sent back to back.
- non-volatile-bit-rate
- serial, 19.2, 38.4, 57.6, 115.2. Setting this value to serial indicates
that the BMC should use the setting used by the IPMI over serial
channel.
- volatile-bit-rate
- serial, 19.2, 38.4, 57.6, 115.2. Setting this value to serial indicates
that the BMC should use the setting used by the IPMI over serial
channel.
- activate [usesolkeepalive | nokeepalive]
[instance=<number>]
-
Causes ipmitool to enter Serial Over LAN mode, and is only
available when using the lanplus interface. An RMCP+ connection is made
to the BMC, the terminal is set to raw mode, and user input is sent to
the serial console on the remote server. On exit, the the SOL payload
mode is deactivated and the terminal is reset to its original
settings.
If the instance is given, it will activate using the given
instance number. The default is 1.
Special escape sequences are provided to control the SOL
session:
- ~. Terminate connection
- ~^Z Suspend ipmitool
- ~^X Suspend ipmitool, but don't restore tty on restart
- ~B Send break
- ~~ Send the escape character by typing it twice
- ~? Print the supported escape sequences
Note that escapes are only recognized immediately after
newline.
- deactivate [instance=<number>]
-
Deactivates Serial Over LAN mode on the BMC. Exiting Serial
Over LAN mode should automatically cause this command to be sent to the
BMC, but in the case of an unintentional exit from SOL mode, this
command may be necessary to reset the state of the BMC.
If the instance is given, it will deactivate the given
instance number. The default is 1.
- spd <i2cbus> <i2caddr>
[<channel>] [<axread>]
-
This command may be used to read SPD (Serial Presence Detect)
data using the I2C Master Write-Read IPMI command.
- sunoem
- cli [<command string> ...]
-
Execute the service processor command line interface commands.
Without any command string, an interactive session is started in the
service processor command line environment. If a command string is
specified, the command string is executed on the service processor and
the connection is closed.
- led
These commands provide a way to get and set the status of LEDs on
a Sun Microsystems server. Use 'sdr list generic' to get a list of devices
that are controllable LEDs. The ledtype parameter is optional and not
necessary to provide on the command line unless it is required by
hardware.
- get <sensorid> [<ledtype>]
-
Get status of a particular LED described by a Generic Device
Locator record in the SDR. A sensorid of all will get the status
of all available LEDS.
- set <sensorid> <ledmode>
[<ledtype>]
-
Set status of a particular LED described by a Generic Device
Locator record in the SDR. A sensorid of all will set the status
of all available LEDS to the specified ledmode and
ledtype.
- LED Mode is required for set operations:
-
OFF Off
ON Steady On
STANDBY 100ms on 2900ms off blink rate
SLOW 1HZ blink rate
FAST 4HZ blink rate
- LED Type is optional:
-
OK2RM Ok to Remove
SERVICE Service Required
ACT Activity
LOCATE Locate
- nacname <ipmi name>
-
Return the full NAC name of a target identified by ipmi
name.
- ping <count> [<q>]
-
Send and receive count packets. Each packet is 64 bytes.
q - Quiet. Displays output only at the start and end of the
process.
- getval <property name>
-
Returns value of specified ILOM property.
- setval <property name> <property value>
[<timeout>]
-
Sets value of ILOM property. If timeout is not specified, the
default value is 5 seconds. NOTE: setval must be executed locally on
host!
- sshkey
- set <userid> <keyfile>
-
This command will allow you to specify an SSH key to use for a
particular user on the Service Processor. This key will be used for CLI
logins to the SP and not for IPMI sessions. View available users and
their userids with the 'user list' command.
- del <userid>
-
This command will delete the SSH key for a specified
userid.
- version
-
Display the version of ILOM firmware.
- getfile <file identifier> <destination file
name>
-
This command will return various files from service processor
and store them in specified destination file. Note that some files may
not be present or be supported by your SP.
File identifiers:
SSH_PUBKEYS
DIAG_PASSED
DIAG_FAILED
DIAG_END_TIME
DIAG_INVENTORY
DIAG_TEST_LOG
DIAG_START_TIME
DIAG_UEFI_LOG
DIAG_TEST_LOG
DIAG_LAST_LOG
DIAG_LAST_CMD
- getbehavior <feature identifier>
-
This command will test if various ILOM features are
enabled.
Feature identifiers:
SUPPORTS_SIGNED_PACKAGES
REQUIRES_SIGNED_PACKAGES
- tsol
This command allows Serial-over-LAN sessions to be established
with Tyan IPMIv1.5 SMDC such as the M3289 or M3290. The default command run
with no arguments will establish default SOL session back to local IP
address. Optional arguments may be supplied in any order.
- <ipaddr>
-
Send receiver IP address to SMDC which it will use to send
serial traffic to. By default this detects the local IP address and
establishes two-way session. Format of ipaddr is XX.XX.XX.XX
- port=NUM
-
Configure UDP port to receive serial traffic on. By default
this is 6230.
- ro|rw
-
Confiure SOL session as read-only or read-write. Sessions are
read-write by default.
- user
- summary
-
Displays a summary of userid information, including maximum
number of userids, the number of enabled users, and the number of fixed
names defined.
- list
-
Displays a list of user information for all defined
userids.
- set
- name <userid> <username>
-
Sets the username associated with the given userid.
- password <userid> [<password>]
-
Sets the password for the given userid. If no password is
given, the password is cleared (set to the NULL password). Be careful
when removing passwords from administrator-level accounts.
- disable <userid>
-
Disables access to the BMC by the given userid.
- enable <userid>
-
Enables access to the BMC by the given userid.
- priv <userid> <privilege level>
[<channel number>]
-
Set user privilege level on the specified channel. If the
channel is not specified, the current channel will be used.
- test <userid> <16|20>
[<password>]
-
Determine whether a password has been stored as 16 or 20
bytes.
The ipmitool open interface utilizes the OpenIPMI kernel device driver.
This driver is present in all modern 2.4 and all 2.6 kernels and it should be
present in recent Linux distribution kernels. There are also IPMI driver
kernel patches for different kernel versions available from the OpenIPMI
homepage.
The required kernel modules is different for 2.4 and 2.6 kernels.
The following kernel modules must be loaded on a 2.4-based kernel in order
for ipmitool to work:
- ipmi_msghandler
- Incoming and outgoing message handler for IPMI interfaces.
- ipmi_kcs_drv
- An IPMI Keyboard Controller Style (KCS) interface driver for the message
handler.
- ipmi_devintf
- Linux character device interface for the message handler.
The following kernel modules must be loaded on a 2.6-based kernel
in order for ipmitool to work:
- ipmi_msghandler
- Incoming and outgoing message handler for IPMI interfaces.
- ipmi_si
- An IPMI system interface driver for the message handler. This module
supports various IPMI system interfaces such as KCS, BT, SMIC, and even
SMBus in 2.6 kernels.
- ipmi_devintf
- Linux character device interface for the message handler.
Once the required modules are loaded there will be a dynamic
character device entry that must exist at /dev/ipmi0. For systems
that use devfs or udev this will appear at /dev/ipmi/0.
To create the device node first determine what dynamic major
number it was assigned by the kernel by looking in /proc/devices and
checking for the ipmidev entry. Usually if this is the first dynamic
device it will be major number 254 and the minor number for the first
system interface is 0 so you would create the device entry with:
mknod /dev/ipmi0 c 254 0
ipmitool includes some sample initialization scripts that can
perform this task automatically at start-up.
In order to have ipmitool use the OpenIPMI device interface you
can specify it on the command line:
ipmitool -I open <command>
The ipmitool bmc interface utilizes the bmc device driver as provided by
Solaris 10 and higher. In order to force ipmitool to make use of this
interface you can specify it on the command line:
ipmitool -I bmc <command>
The following files are associated with the bmc driver:
- /platform/i86pc/kernel/drv/bmc
- 32-bit ELF kernel module for the bmc driver.
- /platform/i86pc/kernel/drv/amd64/bmc
- 64-bit ELF kernel module for the bmc driver.
- /dev/bmc
- Character device node used to communicate with the bmc driver.
The ipmitool lipmi interface uses the Solaris 9 IPMI kernel device
driver. It has been superceeded by the bmc interface on Solaris 10. You
can tell ipmitool to use this interface by specifying it on the command line.
ipmitool -I lipmi <expression>
The ipmitool lan interface communicates with the BMC over an Ethernet LAN
connection using UDP under IPv4. UDP datagrams are formatted to contain IPMI
request/response messages with a IPMI session headers and RMCP headers.
IPMI-over-LAN uses version 1 of the Remote Management Control
Protocol (RMCP) to support pre-OS and OS-absent management. RMCP is a
request-response protocol delivered using UDP datagrams to port 623.
The LAN interface is an authentication multi-session connection;
messages delivered to the BMC can (and should) be authenticated with a
challenge/response protocol with either straight password/key or MD5
message-digest algorithm. ipmitool will attempt to connect with
administrator privilege level as this is required to perform chassis power
functions.
You can tell ipmitool to use the lan interface with the -I
lan option:
ipmitool -I lan -H <hostname>
[-U <username>] [-P <password>]
<command>
A hostname must be given on the command line in order to use the
lan interface with ipmitool. The password field is optional; if you do not
provide a password on the command line, ipmitool will attempt to connect
without authentication. If you specify a password it will use MD5
authentication if supported by the BMC and straight password/key otherwise,
unless overridden with a command line option.
Like the lan interface, the lanplus interface communicates with
the BMC over an Ethernet LAN connection using UDP under IPv4. The difference
is that the lanplus interface uses the RMCP+ protocol as described in
the IPMI v2.0 specification. RMCP+ allows for improved authentication and data
integrity checks, as well as encryption and the ability to carry multiple
types of payloads. Generic Serial Over LAN support requires RMCP+, so the
ipmitool sol activate command requires the use of the lanplus
interface.
RMCP+ session establishment uses a symmetric challenge-response
protocol called RAKP (Remote Authenticated Key-Exchange Protocol)
which allows the negotiation of many options. ipmitool does not yet allow
the user to specify the value of every option, defaulting to the most
obvious settings marked as required in the v2.0 specification.
Authentication and integrity HMACS are produced with SHA1, and encryption is
performed with AES-CBC-128. Role-level logins are not yet supported.
ipmitool must be linked with the OpenSSL library in order
to perform the encryption functions and support the lanplus
interface. If the required packages are not found it will not be compiled in
and supported.
You can tell ipmitool to use the lanplus interface with the
-I lanplus option:
ipmitool -I lanplus -H
<hostname> [-U <username>] [-P
<password>] <command>
A hostname must be given on the command line in order to use the
lan interface with ipmitool. With the exception of the -A and
-C options the rest of the command line options are identical to
those available for the lan interface.
The -C option allows you specify the authentication,
integrity, and encryption algorithms to use for for lanplus session
based on the cipher suite ID found in the IPMIv2.0 specification in table
22-19. The default cipher suite is 3 which specifies RAKP-HMAC-SHA1
authentication, HMAC-SHA1-96 integrity, and AES-CBC-128 encryption
algorightms.
The ipmitool free interface utilizes the FreeIPMI libfreeipmi drivers.
You can tell ipmitool to use the FreeIPMI interface with the -I
option:
ipmitool -I free <command>
The ipmitool imb interface supports the Intel IMB (Intel Inter-module
Bus) Interface through the /dev/imb device.
You can tell ipmitool to use the IMB interface with the -I
option:
ipmitool -I imb <command>
- Example 1: Listing remote sensors
-
> ipmitool -I lan -H 1.2.3.4 -f passfile sdr list
Baseboard 1.25V | 1.24 Volts | ok
Baseboard 2.5V | 2.49 Volts | ok
Baseboard 3.3V | 3.32 Volts | ok
- Example 2: Displaying status of a remote sensor
-
> ipmitool -I lan -H 1.2.3.4 -f passfile sensor get
"Baseboard 1.25V"
Locating sensor record...
Sensor ID : Baseboard 1.25V (0x10)
Sensor Type (Analog) : Voltage
Sensor Reading : 1.245 (+/- 0.039) Volts
Status : ok
Lower Non-Recoverable : na
Lower Critical : 1.078
Lower Non-Critical : 1.107
Upper Non-Critical : 1.382
Upper Critical : 1.431
Upper Non-Recoverable : na
- Example 3: Displaying the power status of a remote chassis
-
> ipmitool -I lan -H 1.2.3.4 -f passfile chassis power
status
Chassis Power is on
- Example 4: Controlling the power on a remote chassis
-
> ipmitool -I lan -H 1.2.3.4 -f passfile chassis power on
Chassis Power Control: Up/On
Duncan Laurie <duncan@iceblink.org>
- IPMItool Homepage
- http://ipmitool.sourceforge.net
- Intelligent Platform Management Interface Specification
- http://www.intel.com/design/servers/ipmi
- OpenIPMI Homepage
- http://openipmi.sourceforge.net
- FreeIPMI Homepage
- http://www.gnu.org/software/freeipmi/
Visit the GSP FreeBSD Man Page Interface. Output converted with ManDoc. |