rwscanquery(1) |
SiLK Tool Suite |
rwscanquery(1) |
rwscanquery - Query the network scan database
rwscanquery [options]
Report Options:
--report=REPORT_TYPE Select query and output options. Values
for REPORT_TYPE are standard, volume,
scanset, scanflows, respflows, and export
--start-date=YYYY/MM/DD:HH Report on scans active after this date.
--end-date=YYYY/MM/DD:HH Defaults to start-date.
--saddress=ADDR_SPEC Show scans originating from matching hosts.
--sipset=IPSET_FILE Show scans originating from hosts in set.
--daddress=IP_WILDCARD Show only scans targeting matching hosts.
--dipset=IPSET_FILE Show only scans targeting hosts in set.
--show-header Display column titles at start of output.
--columnar Display more human-readable columnar view.
--output-path=PATH Write results to the specified file.
Configuration Options:
--database=DBNAME Query an alternate scan database
Help Options:
--help Display this brief help message.
--man Display the full documentation.
--version Display the version information.
rwscanquery queries the network scan database---that is, the database
that contains scans found by rwscan(1). The type of
output rwscanquery creates is controlled by the --report switch
as described in the "Report Options" section below.
rwscanquery writes its output to the location specified by the
--output-path switch or to the standard output when that switch is not
provided.
rwscanquery runs a query of the scan database and then,
depending on the report type, either displays the result set as text or
creates a binary SiLK from the result set. The database rows that are part
of the result set may be limited by using the --start-date,
--end-date, --saddress, and --sipset switches. The
result set is always limited to a time window, and the current day is used
when no --start-date is given.
The following three report types produce textual output. The
default output displays the values separated by a vertical bar
("|") with no spacing. The
--columnar switch causes the output to appear in columns with a
space-delimiter between the columns. The output includes no title line
unless the --show-header switch is specified.
- The "standard" report contains most of
the columns in the database for the rows in the result set. (The columns
containing the scan model and scan probability are not included.)
- The "volume" report groups the rows in
the result set by day and shows sums the flows, packets, and bytes columns
for each day.
- The "export" report contains all the
columns in the database for the rows in the result set, and the rows are
displayed in a format compatible with rwscan.
The following three report types create a binary SiLK file as
their result. These report types invoke other SiLK tools (namely
rwfilter(1), rwset(1),
rwsetbuild(1), and rwsetcat(1))
and the report types assume rwfilter has access to a SiLK data
repository.
The first step in all three of these report types is for
rwscanquery to get the distinct IP addresses for the rows in the
result set and pass them into rwsetbuild to create a temporary IPset
file containing the scanning IPs.
- A "scanflows" report produces a file of
SiLK Flow records whose source IP is a scanning IPs. rwscanquery
uses the temporary IPset as an argument to rwfilter to find flow
records in your data repository that originated from the scanning IPs
within the time window. You may choose to limit the report to particular
IPs targeted by the scanning IPs by specifying the --daddress or
--dipset switches. The output from rwfilter is the output of
the report. The rwfilter invocation uses the configuration values
"rw_in_class" and
"rw_in_type" if they are specified in
the configuration file (c.f. "CONFIGURATION").
- A "respflows" report produces a file of
SiLK Flow records whose destination IP is a scanning IP. These flow
records may represent responses to a scan. To create this report,
rwscanquery performs steps similar to those for the
"scanflows" report except the direction
of the rwfilter command is reversed to find flow records going to
the scanning IPs. You may choose to limit the report to particular IPs
that responded to the scan by specifying the --daddress or
--dipset switches. The output from rwfilter is the output of
the report. The rwfilter invocation uses the configuration values
"rw_out_class" and
"rw_out_type" if they are specified in
the configuration file (c.f. "CONFIGURATION").
- A "scanset" report produces a binary
IPset file.
- If neither the --daddress nor --dipset switches are
specified, the output of the this report is the temporary IPset file
containing the scanning IPs; that is, all the scanning IPs in the time
window.
- Otherwise, rwscanquery performs the same steps it does as when
creating "scanflows" report. Next,
instead of returning the output from rwfilter, rwscanquery
passes the flow records into rwset to create an IPset file
containing the scanning IPs that targeted particular IP addresses.
Option names may be abbreviated if the abbreviation is unique or is an exact
match for an option. A parameter to an option may be specified as
--arg=param or --arg param, though the first form
is required for options that take optional parameters.
- --report=TYPE
- Specify the query and the type of output to create. When this switch is
not specified, the default is a
"standard" report. The supported values
for TYPE are:
- standard
- Write one textual line of output for each scan record in the scan
database. By default, the output has no titles and it is not in columnar
form. Specify the --show-header and/or --columnar switches
to make the output more human readable.
- volume
- Write a daily scan activity volume summary report for each day within the
time period. By default, the output has no titles and it is not in
columnar form. Specify the --show-header and/or --columnar
switches to make the output more human readable.
- scanset
- Write an IPset file containing the IP addresses which were the sources of
scan activity during the selected time period. The output of this report
type is binary, so you must redirect or pipe the output to a location or
specify the --output-path switch.
- scanflows
- Write a SiLK Flow file containing all flows originating from scanning IP
addresses within the specified time period. This flow data includes flows
originating from any host that would be listed as a scan source by your
query, from any time within the time period specified by
--start-date and --end-date. Note that this may include
flows that were not identified by the scan analysis as being part of a
scan. The output of this report type is binary, so you must redirect or
pipe the output to a location or specify the --output-path
switch.
- respflows
- Write a SiLK Flow file containing all flows sent to scanning IP addresses
within the specified time period---that is, possible responses to the
scanners. The output of this report type is binary, so you must redirect
or pipe the output to a location or specify the --output-path
switch.
- export
- Write textual output consistent with the output format of the
rwscan(1) tool. Specify the --show-header
switch to include a title line.
- --start-date=YYYY/MM/DD:HH
- Display scans which were active after this hour. When this argument
contains a date with no hour and no --end-date switch is specified,
scans for that entire day are returned. If this switch is not specified at
all, scans for the current day (based on the local time on the host
machine) are returned.
- --end-date=YYYY/MM/DD:HH
- Display scans which were active before the end of this hour. If no
end-date is given, defaults to the same as start-date. It is an error to
provide an end-date without a start-date.
- --saddress=ADDR_SPEC
- Display scans originating from hosts described in ADDR_SPEC, where
ADDR_SPEC is a list of addresses, address ranges, and CIDR blocks.
Only scans originating from hosts in the list are displayed.
- --sipset=IPSET_FILE
- Display scans originating from hosts in IPSET_FILE, where
IPSET_FILE is a standard SiLK IPset file as created by
rwset(1) or rwsetbuild(1). Note
that a very complex IPset may take a long time to process, or even fail to
return any results.
- --daddress=IP_WILDCARD
- Display scans targeting hosts described in IP_WILDCARD, where
IP_WILDCARD is a single IP address, a single CIDR block, or an IP
Wildcard expression accepted by rwfilter(1). To match
on multiple IPs or networks, use the --dipset switch. This switch
is ignored for --report types other than
"scanset",
"scanflows", and
"respflows".
- --dipset=IPSET_FILE
- Display scans targeting hosts in IPSET_FILE, where
IPSET_FILE is a standard SiLK IPset file. This switch is ignored
for --report types other than
"scanset",
"scanflows", and
"respflows".
- --show-header
- Display a header line giving a short name (or title) for each field when
printing textual output with the
"standard",
"volume", or
"export" report types. By default, no
header is displayed.
- --columnar
- Display output in more human-readable columnar format when printing
textual output with the "standard" or
"volume" report types. When this switch
is not given, the output is presented as data fields delimited by the
| character.
- --output-path=PATH
- Write results to PATH instead of to the standard output.
- --database=DBNAME
- Select a database instance other than the default. The default is
specified by the "db_instance" value in
the configuration file as described in "CONFIGURATION"
below.
- --help
- Display a brief usage message and exit.
- --man
- Display full documentation for rwscanquery and exit.
- --version
- Print the version number and exit the application.
rwscanquery reads configuration information from a file named
.rwscanrc. If the RWSCANRC environment variable is set, it is used as
the location of the .rwscanrc file. When RWSCANRC is not set,
rwscanquery attempts to find a file name .rwscanrc in the
directories specified in the "FILES" section below.
The format of the .rwscanrc file is
name=value pairs, one per line. The configuration parameters
currently read from .rwscanrc are:
- db_driver
- The type of database to connect to. rwscanquery supports
"oracle",
"postgresql",
"mysql", and
"sqlite".
- db_userid
- The userid to use when connecting to the scan database.
- db_password
- The password to use when connecting to the scan database.
- db_instance
- The name of the database instance to connect to if none is provided with
the --database command line switch. If neither this configuration
option nor the --database command line switch are specified, the
hard-coded default database instance "SCAN" is used.
- rw_in_class
- The class for incoming flow data. The
"rw_in_class" and
"rw_in_type" values are used to query
scan flows when the "scanflows" report
type is requested or when the --daddress or --dipset
switches are used for the "scanset"
report type. If not specified, rwfilter's default is used.
- rw_in_type
- The type(s) for incoming flow data. See
"rw_in_class" for details.
- rw_out_class
- The class for outgoing flow data. The
"rw_out_class" and
"rw_out_type" values are used to query
scan flows when the "respflows" report
type is requested. If not specified, rwfilter's default is
used.
- rw_out_type
- The type(s) for outgoing flow data. See
"rw_out_class" for details. (Note that
rwfilter often defaults to querying incoming flows, so this
parameter ought to be specified.)
In the following examples, the dollar sign
("$") represents the shell prompt. The text
after the dollar sign represents the command line. Lines have been wrapped for
improved readability, and the back slash
("\") is used to indicate a wrapped line.
Display information on all scans occurring during the 12:00 hour
(12:00:00 to 12:59:59) of 2009/02/12.
$ rwscanquery --show-header --start-date=2009/02/12:12
scan-id|stime|etime|proto|srcaddr|flows|packets|bytes
499|2009-02-12 12:01:56|2009-02-12 12:08:39|6|10.199.151.231|256|256|10240
365|2009-02-12 12:08:40|2009-02-12 12:14:54|6|10.146.88.117|256|256|10240
57|2009-02-12 12:28:51|2009-02-12 12:34:55|6|10.29.23.160|256|256|10240
627|2009-02-12 11:52:07|2009-02-12 12:41:16|17|10.253.24.230|1023|1023|30175
366|2009-02-12 12:41:50|2009-02-12 12:48:14|6|10.146.89.46|256|256|10240
182|2009-02-12 12:54:39|2009-02-12 13:01:20|6|10.79.26.176|256|256|10240
4|2009-02-12 12:41:19|2009-02-12 13:33:57|17|10.2.47.87|1023|1023|30205
Create the IPset file scan.set containing the scanners
discovered during that hour.
$ rwscanquery --report=scanset --start-date=2009/02/12:12 \
--output-path=scan.set
$ rwsetcat scan.set
10.2.47.87
10.29.23.160
10.79.26.176
10.146.88.117
10.146.89.46
10.199.151.231
10.253.24.230
Repeat the first query but limit the output to scanners coming
from the CIDR block 10.199.0.0/16.
$ rwscanquery --show-header --start-date=2009/02/12:12 \
--saddr=10.199.0.0/16
scan-id|stime|etime|proto|srcaddr|flows|packets|bytes
499|2009-02-12 12:01:56|2009-02-12 12:08:39|6|10.199.151.231|256|256|10240
Expand the query for that CIDR block to include the preceding and
following hours (11:00:00 to 13:59:59).
$ rwscanquery --start-date=2009/02/12:11 --end-date=2009/02/12:13 \
--saddr=10.199.0.0/16
499|2009-02-12 12:01:56|2009-02-12 12:08:39|6|10.199.151.231|256|256|10240
497|2009-02-12 13:33:57|2009-02-12 14:24:35|17|10.199.98.5|1023|1023|30079
Create the IPset file scanning-cidr.set that contains the
CIDR block 10.199.0.0/16, and then search for scans coming from that IP on
Feb 13, 2009.
$ cat scanning-cidr.txt
10.199.0.0/16
$ rwsetbuild scanning-cidr.txt scanning-cidr.set
$
$ rwscanquery --start-date=2009/02/13 --sipset=scanning-cidr.set
500|2009-02-13 22:42:25|2009-02-13 22:48:45|6|10.199.207.32|256|256|10240
Print the volume of data attributed to scans over a three day
period.
$ rwscanquery --report=volume --show-header \
--start-date=2009/02/12 --end-date=2009/02/14
date|flows|packets|bytes
2009/02/12|137452|137499|17149008
2009/02/13|74727|76167|2798040
2009/02/14|76160|76160|2750531
The following limits the volume report to the IPs in the file
scanning-cidr.set and displays the results in columns.
$ rwscanquery --report=volume --show-header --columnar \
--start-date=2009/02/12 --end-date=2009/02/14 \
--sipset=scanning-cidr.set
date flows packets bytes
2009/02/12 1279 1279 40319
2009/02/13 256 256 10240
2009/02/14 256 256 10240
Get the SiLK Flow records coming from the scanners during the
12:00 hour on 2009/02/12 and store in the file scanning-flows.rw.
$ rwscanquery --report=scanflows --start-date=2009/02/12:12 \
--output=scanning-flows.rw
Use rwuniq(1) to summarize the file
scanning-flows.rw.
$ rwuniq --fields=sip --values=flows,packets,bytes \
--sort-output scanning-flows.rw
sIP| Records| Packets| Bytes|
10.2.47.87| 373| 373| 11032|
10.29.23.160| 256| 256| 10240|
10.79.26.176| 203| 203| 8120|
10.146.88.117| 256| 256| 10240|
10.146.89.46| 256| 256| 10240|
10.199.151.231| 256| 256| 10240|
10.253.24.230| 846| 846| 24921|
Run a respflows report to verify that there were no responses to
the scan.
$ rwscanquery --report=respflows --start-date=2009/02/12:12 \
--output=scanning-response.rw
$
$ rwuniq --fields=sip --values=flows,packets,bytes \
--sort-output scanning-response.rw
sIP| Records| Packets| Bytes|
Create the IPset subnet-scan.set for scanners that targeted
the 192.168.186.0/24 CIDR block during the 12:00 hour on 2009/02/12.
$ rwscanquery --report=scanset --start-date=2009/02/12:12 \
--daddress=192.168.186.0/24 --output-path=subnet-scan.set
Store the corresponding flow records for those scans in the file
subset-scan.rw.
$ rwscanquery --report=scanflows --start-date=2009/02/12:12 \
--daddress=192.168.186.0/24 --output-path=subnet-scan.rw
Determine how many IPs in that subnet were targeted.
$ rwuniq --fields=sip --values=flows,distinct:dip subnet-scan.rw
sIP| Records|dIP-Distin|
10.146.89.46| 256| 256|
Display the title line for an export report.
$ rwscanquery --report=export --start-date=2009/02/12:12 \
--show-header | head -1
id|sip|proto|stime|etime|flows|packets|bytes|scan_model|scan_prob
- RWSCANRC
- This environment variable allows the user to specify the location of the
.rwscanrc configuration file. The value may be a complete path or a
file relative to the user's current directory. See the "FILES"
section for standard locations of this file.
- SILK_CLOBBER
- The SiLK tools normally refuse to overwrite existing files. Setting
SILK_CLOBBER to a non-empty value removes this restriction for the report
types of "scanset",
"scanflows", and
"respflows".
- SILK_CONFIG_FILE
- This environment variable is used as the location for the site
configuration file, silk.conf, for report types that use
rwfilter. When this environment variable is not set,
rwfilter searches for the site configuration file in the locations
specified in the "FILES" section.
- SILK_DATA_ROOTDIR
- This environment variable specifies the root directory of data repository
for report types that use rwfilter. This value overrides the
compiled-in value. In addition, rwfilter may use this value when
searching for the SiLK site configuration files. See the "FILES"
section for details.
- SILK_RWFILTER_THREADS
- The number of threads rwfilter uses when reading files from the
data store.
- SILK_PATH
- This environment variable gives the root of the install tree. When
searching for the site configuration file, rwfilter may use this
environment variable. See the "FILES" section for details.
- PATH
- This is the standard UNIX path (c.f., environ(7)).
Depending on the report type, rwscanquery may invoke
rwfilter(1), rwset(1),
rwsetbuild(1), or rwsetcat(1) as
part of its processing.
- RWFILTER
- Complete path to rwfilter. If not set, rwscanquery attempts
to find rwfilter on your PATH.
- RWSET
- Complete path to rwset. If not set, rwscanquery attempts to
find rwset on your PATH.
- RWSETBUILD
- Complete path to rwsetbuild. If not set, rwscanquery
attempts to find rwsetbuild on your PATH.
- RWSETCAT
- Complete path to rwsetcat. If not set, rwscanquery attempts
to find rwsetcat on your PATH.
- ${RWSCANRC}
- ${HOME}/.rwscanrc
- /usr/local/share/silk/.rwscanrc
- Possible locations for the rwscanquery configuration file,
.rwscanrc. In addition, rwscanquery checks the parent
directory of the directory containing the rwscanquery script.
- ${SILK_CONFIG_FILE}
- ${SILK_DATA_ROOTDIR}/silk.conf
- /data/silk.conf
- ${SILK_PATH}/share/silk/silk.conf
- ${SILK_PATH}/share/silk.conf
- /usr/local/share/silk/silk.conf
- /usr/local/share/silk.conf
- Possible locations for the SiLK site configuration file---for report types
that use rwfilter.
rwscan(1), rwfilter(1),
rwset(1), rwsetbuild(1),
rwsetcat(1), rwuniq(1),
silk(7), environ(7)
Visit the GSP FreeBSD Man Page Interface. Output converted with ManDoc. |