DS2423 - 4kbit 1-Wire RAM with Counter

RAM and counters.

1D [.]XXXXXXXXXXXX[XX][/[ counter.[A|B|ALL] | memory | pages/page.[0-15|ALL] | pages/count.[0-15|ALL] | address | crc8 | id | locator | r_address | r_id | r_locator | type ]]

1D

read-only, unsigned integer
Debounced external counter. Associated with RAM page.14 and page.15 Note: counter increments only. It is reset when the chip loses power.
ALL returns the two values, separated by a comma. They are read sequentially.

The property was called counters prior to OWFS version 2.9p1 and the old name is invisibly recognized for backwards compatibility.

read-write, binary
512 bytes of memory.

read-write, binary
Memory is split into 16 pages of 32 bytes each. Memory is RAM, contents are lost when power is lost. ALL is an aggregate of the pages. Each page is accessed sequentially.

read-only, unsigned integer

Write access to each page of memory. Actually only page.12 and page.13 have write counters.
page14 and page.15 ´s counters are associated with the external counters.A and counters.B triggers.
The value 0xFFFFFFFF is returned for pages/count.0 through pages/count.11
ALL is an aggregate of the counters, comma separated. Each page is accessed sequentially.

read-only, ascii
The entire 64-bit unique ID. Given as upper case hexadecimal digits (0-9A-F).
address starts with the family code
r address is the address in reverse order, which is often used in other applications and labeling.

read-only, ascii
The 8-bit error correction portion. Uses cyclic redundancy check. Computed from the preceding 56 bits of the unique ID number. Given as upper case hexadecimal digits (0-9A-F).

read-only, ascii
The 8-bit family code. Unique to each type of device. Given as upper case hexadecimal digits (0-9A-F).

read-only, ascii
The 48-bit middle portion of the unique ID number. Does not include the family code or CRC. Given as upper case hexadecimal digits (0-9A-F).
r id is the id in reverse order, which is often used in other applications and labeling.

read-only, ascii
Uses an extension of the 1-wire design from iButtonLink company that associated 1-wire physical connections with a unique 1-wire code. If the connection is behind a Link Locator the locator will show a unique 8-byte number (16 character hexadecimal) starting with family code FE.
If no Link Locator is between the device and the master, the locator field will be all FF.
r locator is the locator in reverse order.

read-only, yes-no
Is the device currently present on the 1-wire bus?

read-only, ascii
Part name assigned by Dallas Semi. E.g. DS2401 Alternative packaging (iButton vs chip) will not be distiguished.

None.

1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connector scheme where the data line can also provide power.

Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices, including memory, sensors (humidity, temperature, voltage, contact, current), switches, timers and data loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There are also 1-wire devices that have encryption included.

The 1-wire scheme uses a single bus master and multiple slaves on the same wire. The bus master initiates all communication. The slaves can be individually discovered and addressed using their unique ID.

Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters.

OWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The underlying principle is to create a virtual filesystem, with the unique ID being the directory, and the individual properties of the device are represented as simple files that can be read and written.

Details of the individual slave or master design are hidden behind a consistent interface. The goal is to provide an easy set of tools for a software designer to create monitoring or control applications. There are some performance enhancements in the implementation, including data caching, parallel access to bus masters, and aggregation of device communication. Still the fundamental goal has been ease of use, flexibility and correctness rather than speed.

The DS2423 (3) is used for its counters. The internal counters (associated with pages 12 and 13) can detect memory tampering.

The external counters A and B page been used in circuit design, such as a wind anometer. OWFS system handles this automatically.

All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form:
Family Code
8 bits
Address
48 bits
CRC
8 bits

Addressing under OWFS is in hexadecimal, of form:

01.123456789ABC

where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address.

The dot is optional, and the CRC code can included. If included, it must be correct.

http://pdfserv.maxim-ic.com/en/ds/DS2423.pdf

owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite (1) owpresent (1) owtap (1)

owfs (5) owtap (1) owmon (1)

owtcl (3) owperl (3) owcapi (3)

DS1427 (3) DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3)

DS2401 (3) DS2411 (3) DS1990A (3)

DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3) DS1996 (3) DS2430A (3) DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3)

DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3) InfernoEmbedded (3)

DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)

DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)

DS2450 (3)

DS2890 (3)

DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)

DS2423 (3)

LCD (3) DS2408 (3)

DS1977 (3)

DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)

EEEF (3) DS2438 (3)

http://www.owfs.org

Paul Alfille (paul.alfille@gmail.com)
2003 OWFS Manpage

Search for    or go to Top of page |  Section 3 |  Main Index

Powered by GSP Visit the GSP FreeBSD Man Page Interface.
Output converted with ManDoc.