SNMP::Info::CiscoStack(3) |
User Contributed Perl Documentation |
SNMP::Info::CiscoStack(3) |
SNMP::Info::CiscoStack - SNMP Interface to data from CISCO-STACK-MIB
# Let SNMP::Info determine the correct subclass for you.
my $ciscostack = new SNMP::Info(
AutoSpecify => 1,
Debug => 1,
DestHost => 'myswitch',
Community => 'public',
Version => 2
)
or die "Can't connect to DestHost.\n";
my $class = $ciscostack->class();
print "SNMP::Info determined this device to fall under subclass : $class\n";
SNMP::Info::CiscoStack is a subclass of SNMP::Info that provides an interface to
the "CISCO-STACK-MIB". This MIB is used
across the Catalyst family under CatOS and IOS.
Use or create in a subclass of SNMP::Info. Do not use
directly.
- $stack->broadcast()
- ("sysBroadcast")
- $stack->fan()
- ("chassisFanStatus")
- $stack->model()
- ("chassisModel")
- $stack->netmask()
- ("sysNetMask")
- $stack->ps1_type()
- ("chassisPs1Type")
- $stack->ps2_type()
- ("chassisPs2Type")
- $stack->ps1_status()
- ("chassisPs1Status")
- $stack->ps2_status()
- ("chassisPs2Status")
- $stack->serial()
- ("chassisSerialNumberString") or
("chassisSerialNumber")
- $stack->slots()
- ("chassisNumSlots")
- $stack->i_physical()
- Returns a map to IID for ports that are physical ports, not vlans,
etc.
- $stack->i_type()
- Crosses p_port() with p_type() and returns the results.
Overrides with "ifType" if
p_type() isn't available.
- $stack->i_duplex()
- Returns reference to hash of iid to current link duplex setting.
First checks for fixed gigabit ports which are always full
duplex. Next, if the port is not operational and reported port duplex
("portDuplex") is auto then the
operational duplex can not be determined. Otherwise it uses the reported
port duplex ("portDuplex").
- $stack->i_duplex_admin()
- Returns reference to hash of iid to administrative duplex setting.
First checks for fixed gigabit ports which are always full
duplex. Next checks the port administrative speed
("portAdminSpeed") which if set to
autonegotiate then the duplex will also autonegotiate, otherwise it uses
the reported port duplex
("portDuplex").
- $stack->i_speed_admin()
- Returns reference to hash of iid to administrative speed setting.
"portAdminSpeed"
- $stack->set_i_speed_admin(speed, ifIndex)
-
Sets port speed, must be supplied with speed and port C<ifIndex>
Speed choices are 'auto', '10', '100', '1000'
Crosses $stack->p_port() with $stack->p_duplex() to
utilize port C<ifIndex>.
Example:
my %if_map = reverse %{$stack->interfaces()};
$stack->set_i_speed_admin('auto', $if_map{'FastEthernet0/1'})
or die "Couldn't change port speed. ",$stack->error(1);
- $stack->set_i_duplex_admin(duplex, ifIndex)
-
Sets port duplex, must be supplied with duplex and port C<ifIndex>
Speed choices are 'auto', 'half', 'full'
Crosses $stack->p_port() with $stack->p_duplex() to
utilize port C<ifIndex>.
Example:
my %if_map = reverse %{$stack->interfaces()};
$stack->set_i_duplex_admin('auto', $if_map{'FastEthernet0/1'})
or die "Couldn't change port duplex. ",$stack->error(1);
This table holds configuration information for each of the blades installed in
the Catalyst device.
- $stack->m_type()
- ("moduleType")
- $stack->m_model()
- ("moduleModel")
- $stack->m_serial()
- ("moduleSerialNumber")
- $stack->m_status()
- ("moduleStatus")
- $stack->m_name()
- ("moduleName")
- $stack->m_ports()
- ("moduleNumPorts")
- $stack->m_ports_status()
- Returns a list of space separated status strings for the ports.
To see the status of port 4 :
@ports_status = split(' ', $stack->m_ports_status() );
$port4 = $ports_status[3];
("modulePortStatus")
- $stack->m_ports_hwver()
- ("moduleHwVersion")
- $stack->m_ports_fwver()
- ("moduleFwVersion")
- $stack->m_ports_swver()
- ("moduleSwVersion")
- $stack->m_ports_ip()
- ("moduleIPAddress")
- $stack->m_ports_sub1()
- ("moduleSubType")
- $stack->m_ports_sub2()
- ("moduleSubType2")
- $stack->m_ip()
- ("moduleIPAddress")
- $stack->m_sub1()
- ("moduleSubType")
- $stack->m_sub2()
- ("moduleSubType2")
- $stack->p_name()
- ("portName")
- $stack->p_type()
- ("portType")
- $stack->p_status()
- ("portOperStatus")
- $stack->p_status2()
- ("portAdditionalStatus")
- $stack->p_speed()
- ("portAdminSpeed")
- $stack->p_duplex()
- ("portDuplex")
- $stack->p_port()
- ("portIfIndex")
- $stack->p_rx_flow_control()
- Can be either "on"
"off" or
"disagree"
"Indicates the receive flow control operational status of
the port. If the port could not agree with the far end on a link
protocol, its operational status will be disagree(3)."
"portOperRxFlowControl"
- $stack->p_tx_flow_control()
- Can be either "on"
"off" or
"disagree"
"Indicates the transmit flow control operational status
of the port. If the port could not agree with the far end on a link
protocol, its operational status will be disagree(3)."
"portOperTxFlowControl"
- $stack->p_rx_flow_control_admin()
- Can be either "on"
"off" or
"desired"
"Indicates the receive flow control administrative status
set on the port. If the status is set to on(1), the port will
require the far end to send flow control. If the status is set to
off(2), the port will not allow far end to send flow control. If
the status is set to desired(3), the port will allow the far end
to send the flow control."
"portAdminRxFlowControl"
- $stack->p_tx_flow_control_admin()
- Can be either "on"
"off" or
"desired"
"Indicates the transmit flow control administrative
status set on the port. If the status is set to on(1), the port
will send flow control to the far end. If the status is set to
off(2), the port will not send flow control to the far end. If
the status is set to desired(3), the port will send flow control
to the far end if the far end supports it."
"portAdminTxFlowControl"
- $stack->p_speed_admin()
- ("portCpbSpeed")
- $stack->p_duplex_admin()
- ("portCpbDuplex")
- $stack->munge_port_status()
- Munges binary byte describing each port into ascii, and returns an ascii
list separated by spaces.
Visit the GSP FreeBSD Man Page Interface. Output converted with ManDoc. |