OBI2NCID.CONF(5) NCID OBI2NCID.CONF(5)

obi2ncid.conf - obi2ncid configuration file

The obi2ncid.conf file contains the configuration information for obi2ncid.

The obi2ncid.conf file understands 3 types of lines:

blank line
ignored
comment line, beginning with '#'
ignored
VARIABLE = VALUE
VALUE can contain spaces if it is between quotes.

See obi2ncid.conf for all default values.

verbose = level
Level is in the range 1-9. Not all verbose levels are used.
HostnameFlag = value
Value is 0 or 1. Includes hostname in the IDENT string if 1.
ncidaddr = host address
The NCID server host address can be an IP address or a resolvable host name.
ncidport = port
The NCID server port number.
delay = seconds
If the connection to the NCID server is lost, this specifies the number of seconds between reconnection attempts.
obiport = port
The NCID gateway listen port.
lineid = string
The telephone line identification

Set the NCID server IP address:

ncidaddr = 192.168.1.20

Set gateway listen port

obiport = 4335