NAMEsane-plustek - SANE backend for LM983[1/2/3] based USB flatbed scannersDESCRIPTIONThe sane-plustek library implements a SANE (Scanner Access Now Easy) backend that provides access to USB flatbed scanners based on National Semiconductor Merlin chipsets (LM9831, 9832 and 9833). If you're looking for parallel-port support for Plustek scanner please refer to the sane-plustek_pp(5) backend.SUPPORTED DEVICESThe Backend is able to support USB scanner based on the National Semiconductor chipsets LM9831, LM9832 and LM9833. The following tables show various devices which are currently reported to work. If your Plustek scanner has another Product ID, then the device is NOT supported by this backend.Vendor Plustek - ID: 0x07B3
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- OpticPro U12 LM9831 600x1200dpi 42bit 512Kb 0x0010 OpticPro UT12 LM9831 600x1200dpi 42bit 512Kb 0x0013 OpticPro UT12 LM9832 600x1200dpi 42bit 512Kb 0x0017 OpticPro UT16 LM9832 600x1200dpi 42bit 512Kb 0x0017 OpticPro U24 LM9831 1200x2400dpi 42bit 2Mb 0x0011 OpticPro U24 LM9832 1200x2400dpi 42bit 2Mb 0x0015 OpticPro UT24 LM9832 1200x2400dpi 42bit 2Mb 0x0017 Vendor KYE/Genius - ID: 0x0458
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- Colorpage HR6 V2 LM9832 600x1200dpi 42bit 512Kb 0x2007 Colorpage HR6 V2 LM9832 600x1200dpi 42bit 512Kb 0x2008 Colorpage HR6A LM9832 600x1200dpi 42bit 512Kb 0x2009 Colorpage HR7 LM9832 600x1200dpi 42bit 512Kb 0x2013 Colorpage HR7LE LM9832 600x1200dpi 42bit 512Kb 0x2015 Colorpage HR6X LM9832 600x1200dpi 42bit 512Kb 0x2016 Vendor Hewlett-Packard - ID: 0x03F0
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- ScanJet 2100C LM9831 600x1200dpi 42bit 512Kb 0x0505 ScanJet 2200C LM9832 600x1200dpi 42bit 512Kb 0x0605 Vendor Mustek - ID: 0x0400
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- BearPaw 1200 LM9831 600x1200dpi 42bit 512Kb 0x1000 BearPaw 1200 LM9832 600x1200dpi 42bit 512Kb 0x1001* BearPaw 2400 LM9832 1200x2400dpi 42bit 2Mb 0x1001* see also description for model override switch below! Vendor UMAX - ID: 0x1606
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- UMAX 3400 LM9832 600x1200dpi 42bit 512Kb 0x0050 UMAX 3400/3450 LM9832 600x1200dpi 42bit 512Kb 0x0060 UMAX 5400 LM9832 1200x2400dpi 42bit 512Kb 0x0160 Vendor COMPAQ - ID: 0x049F
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- S4-100 LM9832 600x1200dpi 42bit 512Kb 0x001A Vendor Epson - ID: 0x04B8
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- Perfection 1250 LM9832 1200x2400dpi 42bit 512Kb 0x010F Perfection 1260 LM9832 1200x2400dpi 42bit 512Kb 0x011D Vendor CANON - ID: 0x04A9
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- CanoScan N650/656U LM9832 600x1200dpi 42bit 512Kb 0x2206 CanoScan N1220U LM9832 1200x2400dpi 42bit 512Kb 0x2207 CanoScan D660U LM9832 600x1200dpi 42bit 512Kb 0x2208 CanoScan N670/676U LM9833 600x1200dpi 48bit 512Kb 0x220D CanoScan N1240U LM9833 1200x2400dpi 48bit 512Kb 0x220E CanoScan LIDE20 LM9833 600x1200dpi 48bit 512Kb 0x220D CanoScan LIDE25 LM9833 1200x2400dpi 48bit 512Kb 0x2220 CanoScan LIDE30 LM9833 1200x2400dpi 48bit 512Kb 0x220E Vendor Syscan - ID: 0x0A82
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- Travelscan 662 LM9833 600x1200dpi 48bit 512Kb 0x6620 Travelscan 464 LM9833 600x1200dpi 48bit 512Kb 0x4600 Vendor Portable Peripheral Co., Ltd. - ID: 0x0A53
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- Q-Scan USB001 LM9832 300x600dpi 42bit 512Kb 0x1000 Q-Scan USB201 LM9832 300x600dpi 42bit 512Kb 0x2000 Vendor Visioneer - ID: 0x04A7
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- Strobe XP100 LM9833 600x1200dpi 48bit 512Kb 0x0427 OTHER PLUSTEK SCANNERSFor parallelport device support see the sane-plustek_pp(5) backend.The SCSI scanner OpticPro 19200S is a rebadged Artec AM12S scanner and is supported by the sane-artec(5) backend. Only the National Semiconductor LM983[1/2/] based devices of Plustek are supported by this backend. Older versions of the U12, the UT12, the U1212 and U1248 (GrandTech chipset) are not supported. Model Chipset backend ------------------------------------ U1248 GrandTech gt68xx UT16B GrandTech gt68xx OpticSlim 1200 GrandTech gt68xx OpticSlim 2400 GrandTech gt68xx U12 P98003 u12 UT12 P98003 u12 1212U P98003 u12For a more complete and up to date list see: http://www.sane-project.org/sane-supported-devices.html. CONFIGURATIONTo use your scanner with this backend, you need at least two entries in the configuration file /usr/local/etc/sane.d/plustek.conf[usb] vendor-id product-id
[usb] tells the backend, that the following devicename
(here /dev/usbscanner) has to be interpreted as USB scanner device.
If vendor- and product-id has not been specified, the backend tries to
detect this by its own. If device is set to auto then the next
matching device is used.
The Options: option warmup t t specifies the warmup period in seconds, if set
to -1, the automatic warmup function will be used
option lampOff t t is the time in seconds for switching off the
lamps in standby mode
option lOffonEnd b b specifies the behaviour when closing the
backend, 1 --> switch lamps off, 0 --> do not change lamp status
option mov m m is the model override switch. It works only with
Mustek BearPaw devices.
m/PID | 0x1000 | 0x1001 ------+--------------+-------------- 0 | BearPaw 1200 | BearPaw 2400 1 | no function | BearPaw 1200 option invertNegatives b b 0 --> do not invert the picture during
negative scans,
1 --> invert picture option cacheCalData b b 0 --> do not save calibration results,
1 --> save results of calibration in ~/.sane/ directory option altCalibration b b 0 --> use standard calibration routines,
1 --> use alternate calibration (only non Plustek devices, standard for CIS devices) option skipFine b b 0 --> perform fine calibration,
1 --> skip fine calibration (only non Plustek devices) option skipFineWhite b b 0 --> perform white fine calibration,
1 --> skip white fine calibration (only non Plustek devices) option skipDarkStrip b b 0 --> perform dark calibration, with enabled
lamp using the dark calibration strip of the scanner. If the scanner does not
have such a strip, the alternative way is to switch off the lamp during this
step.
1 --> always switch off the lamp for dark calibration, even a black strip is available option skipCalibration b b 0 --> perform calibration,
1 --> skip calibration (only non Plustek devices) option enableTPA b b 0 --> default behaviour, specified by the
internal tables,
1 --> override internal tables and allow TPA mode (EPSON/UMAX only) option posOffX x
x y By using this settings, the user can adjust
the given image positions. Please note, that there's no internal range
checking for this feature.
option posShadingY p
p overrides the internal shading position. The
values are in steps. Please note, that there's no internal range checking
for this feature.
option redGamma r
r g b gr
By using these values, the internal linear gamma table (r,g,b,gr = 1.0) can be
adjusted.
option red_gain r
r g b ro go bo These values can be used to set the
gain and offset values of the AFE for each channel. The range is between 0 and
63. -1 means autocalibration.
See the plustek.conf file for examples. Note:
Note:
FILES
ENVIRONMENT
SEE ALSOsane(7), sane-usb(5), sane-u12(5), sane-gt68xx(5), sane-stek_pp(5), sane-find-scanner(1), scanimage(1)/usr/local/share/doc/sane-backends/plustek/Plustek-USB.changes CONTACT AND BUG-REPORTSPlease send any information and bug-reports to:SANE Mailing List Additional info and hints can be obtained from our
To obtain debug messages from the backend, please set the environment-variable SANE_DEBUG_PLUSTEK before calling your favorite scan-frontend (i.e. scanimage(1)),i.e.: export SANE_DEBUG_PLUSTEK=20 ; scanimage The value controls the verbosity of the backend. Please note, that values greater than 24 force the backend to output raw data files, which could be rather large. The ending of these files is ".raw". For problem reports it should be enough the set the verbosity to 13. KNOWN BUGS & RESTRICTIONS* The driver does not support these manic scalings up to 16 times the physical resolution. The only scaling is done on resolutions between the physical resolution of the CCD-/CIS-sensor and the stepper motor i.e. you have a 600x1200 dpi scanner and you are scanning using 800dpi, so scaling is necessary, because the sensor only delivers 600dpi but the motor is capable to perform 1200dpi steps.* Plusteks' model policy is somewhat inconsistent. They sell technically different devices under the same product name. Therefore it is possible that some devices like the UT12 or U12 won't work - please check the model list above and compare the product-id to the one your device has. * Negative/Slide scanning quality is poor.
Visit the GSP FreeBSD Man Page Interface. |