sane-sm3600(5) SANE Scanner Access Now Easy sane-sm3600(5)

sane-sm3600 - SANE backend for Microtek scanners with M011 USB chip

The sane-sm3600 library implements a SANE (Scanner Access Now Easy) backend that provides access to some Microtek scanners with the Toshiba M011 custom USB chip. This backend should be considered alpha.

There are also backends for Microtek scanners with SCSI command set. Refer to sane-microtek(5) and sane-microtek2(5) for details.

At present, the following scanners are known positively to work with this backend:

Vendor     Product id:     Remark:
--------   --------------  -----------
Microtek   ScanMaker 3600  all modes ok
Microtek   ScanMaker 3700  reported to work
Microtek   ScanMaker 3750  reported to work

If you own a Microtek scanner with the M011 chip other than the ones listed above, it may or may not work with SANE!

This backend dynamically enables the options for the frontend, that are supported by the scanner dependent on the scanning-mode and other options. Unsupported options are disabled.

The following options are supported by the sane-sm3600 backend: Color, grayscale, halftone and lineart scans. Also contrast, brightness, and gamma correction.

This backend does not support device names in a standardized form.

This backend does not support a configuration file right now.

/usr/local/lib/sane/libsane-sm3600.a
The static library implementing this backend.
/usr/local/lib/sane/libsane-sm3600.so
The shared library implementing this backend (present on systems that support dynamic loading).

SANE_DEBUG_SM3600
If the library was compiled with debug support enabled, this environment variable controls the debug level for this backend. E.g., a value of 128 requests all debug output to be printed. Smaller levels reduce verbosity. To see error messages on stderr set SANE_DEBUG_SM3600 to 1.

E.g. just say:
export SANE_DEBUG_SM3600=5

sane(7), sane-microtek(5), sane-microtek2(5)
http://sm3600.sourceforge.net

Marian Eichholz <eichholz@computer.org>
Glenn Ramsey <glenn@componic.com>