|
|
| |
xorg.conf(5) |
FreeBSD File Formats Manual |
xorg.conf(5) |
xorg.conf, xorg.conf.d - configuration files for Xorg X server
Xorg supports several mechanisms for supplying/obtaining configuration
and run-time parameters: command line options, environment variables, the
xorg.conf and xorg.conf.d configuration files, auto-detection, and fallback
defaults. When the same information is supplied in more than one way, the
highest precedence mechanism is used. The list of mechanisms is ordered from
highest precedence to lowest. Note that not all parameters can be supplied via
all methods. The available command line options and environment variables (and
some defaults) are described in the Xserver(1) and Xorg(1) manual pages. Most
configuration file parameters, with their defaults, are described below.
Driver and module specific configuration parameters are described in the
relevant driver or module manual page.
Xorg uses a configuration file called xorg.conf and files ending
in the suffix .conf from the directory xorg.conf.d for its
initial setup. The xorg.conf configuration file is searched for in the
following places when the server is started as a normal user:
/etc/X11/<cmdline>
/usr/local/etc/X11/<cmdline>
/etc/X11/$XORGCONFIG
/usr/local/etc/X11/$XORGCONFIG
/etc/X11/xorg.conf
/etc/xorg.conf
/usr/local/etc/X11/xorg.conf.<hostname>
/usr/local/etc/X11/xorg.conf
/usr/local/lib/X11/xorg.conf.<hostname>
/usr/local/lib/X11/xorg.conf
where <cmdline> is a relative path (with no
“..” components) specified with the -config command
line option, $XORGCONFIG is the relative path (with no
“..” components) specified by that environment variable, and
<hostname> is the machine's hostname as reported by
gethostname(3).
When the Xorg server is started by the “root” user,
the config file search locations are as follows:
<cmdline>
/etc/X11/<cmdline>
/usr/local/etc/X11/<cmdline>
$XORGCONFIG
/etc/X11/$XORGCONFIG
/usr/local/etc/X11/$XORGCONFIG
/etc/X11/xorg.conf
/etc/xorg.conf
/usr/local/etc/X11/xorg.conf.<hostname>
/usr/local/etc/X11/xorg.conf
/usr/local/lib/X11/xorg.conf.<hostname>
/usr/local/lib/X11/xorg.conf
where <cmdline> is the path specified with the
-config command line option (which may be absolute or relative),
$XORGCONFIG is the path specified by that environment variable
(absolute or relative), $HOME is the path specified by that
environment variable (usually the home directory), and
<hostname> is the machine's hostname as reported by
gethostname(3).
Additional configuration files are searched for in the following
directories when the server is started as a normal user:
/etc/X11/<cmdline>
/usr/local/etc/X11/<cmdline>
/etc/X11/xorg.conf.d
/usr/local/etc/X11/xorg.conf.d
where <cmdline> is a relative path (with no
“..” components) specified with the -configdir command
line option.
When the Xorg server is started by the “root” user,
the config directory search locations are as follows:
<cmdline>
/etc/X11/<cmdline>
/usr/local/etc/X11/<cmdline>
/etc/X11/xorg.conf.d
/usr/local/etc/X11/xorg.conf.d
where <cmdline> is the path specified with the
-configdir command line option (which may be absolute or
relative).
Finally, configuration files will also be searched for in a
directory reserved for system use. This is to separate configuration files
from the vendor or 3rd party packages from those of local administration.
These files are found in the following directory:
/usr/local/share/X11/xorg.conf.d
The xorg.conf and xorg.conf.d files are composed of
a number of sections which may be present in any order, or omitted to use
default configuration values. Each section has the form:
Section "SectionName"
SectionEntry
...
EndSection
The section names are:
Files File pathnames
ServerFlags Server flags
Module Dynamic module loading
Extensions Extension enabling
InputDevice Input device description
InputClass Input class description
OutputClass Output class description
Device Graphics device description
VideoAdaptor Xv video adaptor description
Monitor Monitor description
Modes Video modes descriptions
Screen Screen configuration
ServerLayout Overall layout
DRI DRI-specific configuration
Vendor Vendor-specific configuration
The following obsolete section names are still recognised for
compatibility purposes. In new config files, the InputDevice section
should be used instead.
Keyboard Keyboard configuration
Pointer Pointer/mouse configuration
The old XInput section is no longer recognised.
The ServerLayout sections are at the highest level. They
bind together the input and output devices that will be used in a session.
The input devices are described in the InputDevice sections. Output
devices usually consist of multiple independent components (e.g., a graphics
board and a monitor). These multiple components are bound together in the
Screen sections, and it is these that are referenced by the
ServerLayout section. Each Screen section binds together a
graphics board and a monitor. The graphics boards are described in the
Device sections, and the monitors are described in the Monitor
sections.
Config file keywords are case-insensitive, and “_”
characters are ignored. Most strings (including Option names) are
also case-insensitive, and insensitive to white space and “_”
characters.
Each config file entry usually takes up a single line in the file.
They consist of a keyword, which is possibly followed by one or more
arguments, with the number and types of the arguments depending on the
keyword. The argument types are:
Integer an integer number in decimal, hex or octal
Real a floating point number
String a string enclosed in double quote marks (")
Note: hex integer values must be prefixed with “0x”,
and octal values with “0”.
A special keyword called Option may be used to provide
free-form data to various components of the server. The Option
keyword takes either one or two string arguments. The first is the option
name, and the optional second argument is the option value. Some commonly
used option value types include:
Integer an integer number in decimal, hex or octal
Real a floating point number
String a sequence of characters
Boolean a boolean value (see below)
Frequency a frequency value (see below)
Note that all Option values, not just strings, must
be enclosed in quotes.
Boolean options may optionally have a value specified. When no
value is specified, the option's value is TRUE. The following boolean
option values are recognised as TRUE:
1, on, true, yes
and the following boolean option values are recognised as
FALSE:
0, off, false, no
If an option name is prefixed with "No", then the
option value is negated.
Example: the following option entries are equivalent:
Option "Accel" "Off"
Option "NoAccel"
Option "NoAccel" "On"
Option "Accel" "false"
Option "Accel" "no"
Frequency option values consist of a real number that is
optionally followed by one of the following frequency units:
Hz, k, kHz, M,
MHz
When the unit name is omitted, the correct units will be
determined from the value and the expectations of the appropriate range of
the value. It is recommended that the units always be specified when using
frequency option values to avoid any errors in determining the value.
The Files section is used to specify some path names required by the
server. Some of these paths can also be set from the command line (see
Xserver(1) and Xorg(1)). The command line settings override the
values specified in the config file. The Files section is optional, as
are all of the entries that may appear in it.
The entries that can appear in this section are:
- FontPath "path"
- sets the search path for fonts. This path is a comma separated list of
font path elements which the Xorg server searches for font databases.
Multiple FontPath entries may be specified, and they will be
concatenated to build up the fontpath used by the server. Font path
elements can be absolute directory paths, catalogue directories or a font
server identifier. The formats of the later two are explained below:
Catalogue directories:
Catalogue directories can be specified using the prefix
catalogue: before the directory name. The directory can then be
populated with symlinks pointing to the real font directories, using the
following syntax in the symlink name:
<identifier>:[attribute]:pri=<priority>
where <identifier> is an alphanumeric identifier,
[attribute] is an attribute which will be passed to the underlying
FPE and <priority> is a number used to order the fontfile FPEs.
Examples:
75dpi:unscaled:pri=20 -> /usr/share/X11/fonts/75dpi
gscript:pri=60 -> /usr/share/fonts/default/ghostscript
misc:unscaled:pri=10 -> /usr/share/X11/fonts/misc
Font server identifiers:
Font server identifiers have the form:
<trans>/<hostname>:<port-number>
where <trans> is the transport type to use to connect
to the font server (e.g., unix for UNIX-domain sockets or tcp
for a TCP/IP connection), <hostname> is the hostname of the
machine running the font server, and <port-number> is the port
number that the font server is listening on (usually 7100).
When this entry is not specified in the config file, the server
falls back to the compiled-in default font path, which contains the
following font path elements (which can be set inside a catalogue
directory):
/usr/local/share/fonts/X11/misc/
/usr/local/share/fonts/X11/TTF/
/usr/local/share/fonts/X11/OTF/
/usr/local/share/fonts/X11/Type1/
/usr/local/share/fonts/X11/100dpi/
/usr/local/share/fonts/X11/75dpi/
Font path elements that are found to be invalid are removed from
the font path when the server starts up.
- ModulePath "path"
- sets the search path for loadable Xorg server modules. This path is a
comma separated list of directories which the Xorg server searches for
loadable modules loading in the order specified. Multiple
ModulePath entries may be specified, and they will be concatenated
to build the module search path used by the server. The default module
path is
/usr/local/lib/xorg/modules
- XkbDir "path"
- sets the base directory for keyboard layout files. The -xkbdir
command line option can be used to override this. The default directory
is
/usr/local/share/X11/xkb
In addition to options specific to this section (described below), the
ServerFlags section is used to specify some global Xorg server options.
All of the entries in this section are Options, although for
compatibility purposes some of the old style entries are still recognised.
Those old style entries are not documented here, and using them is
discouraged. The ServerFlags section is optional, as are the entries
that may be specified in it.
Options specified in this section (with the exception of
the "DefaultServerLayout" Option) may be overridden
by Options specified in the active ServerLayout section.
Options with command line equivalents are overridden when their command line
equivalent is used. The options recognised by this section are:
- Option "Debug" "string"
- This comma-separated list provides a way to control various debugging
switches from the config file. At the moment the only defined value is
dmabuf_capable which instructs glamor to enable some unstable
buffer management code.
- Option "DefaultServerLayout"
"layout-id"
- This specifies the default ServerLayout section to use in the
absence of the -layout command line option.
- Option "NoTrapSignals"
"boolean"
- This prevents the Xorg server from trapping a range of unexpected fatal
signals and exiting cleanly. Instead, the Xorg server will die and drop
core where the fault occurred. The default behaviour is for the Xorg
server to exit cleanly, but still drop a core file. In general you never
want to use this option unless you are debugging an Xorg server problem
and know how to deal with the consequences.
- Option "DontVTSwitch"
"boolean"
- This disallows the use of the Ctrl+Alt+Fn sequence (where
Fn refers to one of the numbered function keys). That sequence is
normally used to switch to another "virtual terminal" on
operating systems that have this feature. When this option is enabled,
that key sequence has no special meaning and is passed to clients.
Default: off.
- Option "DontZap" "boolean"
- This disallows the use of the Terminate_Server XKB action (usually
on Ctrl+Alt+Backspace, depending on XKB options). This action is normally
used to terminate the Xorg server. When this option is enabled, the action
has no effect. Default: off.
- Option "DontZoom" "boolean"
- This disallows the use of the Ctrl+Alt+Keypad-Plus and
Ctrl+Alt+Keypad-Minus sequences. These sequences allows you to
switch between video modes. When this option is enabled, those key
sequences have no special meaning and are passed to clients. Default:
off.
- Option "DisableVidModeExtension"
"boolean"
- This disables the parts of the VidMode extension used by the xvidtune
client that can be used to change the video modes. Default: the VidMode
extension is enabled.
- Option "AllowNonLocalXvidtune"
"boolean"
- This allows the xvidtune client (and other clients that use the VidMode
extension) to connect from another host. Default: off.
- Option "AllowMouseOpenFail"
"boolean"
- This tells the mousedrv(4) and vmmouse(4) drivers to not report failure if
the mouse device can't be opened/initialised. It has no effect on the
evdev(4) or other drivers. Default: false.
- Option "BlankTime" "time"
- sets the inactivity timeout for the blank phase of the screensaver.
time is in minutes. This is equivalent to the Xorg server's
-s flag, and the value can be changed at run-time with
xset(1). Default: 10 minutes.
- Option "StandbyTime" "time"
- sets the inactivity timeout for the standby phase of DPMS mode.
time is in minutes, and the value can be changed at run-time with
xset(1). Default: 10 minutes. This is only suitable for VESA DPMS
compatible monitors, and may not be supported by all video drivers. It is
only enabled for screens that have the "DPMS" option set
(see the MONITOR section below).
- Option "SuspendTime" "time"
- sets the inactivity timeout for the suspend phase of DPMS mode.
time is in minutes, and the value can be changed at run-time with
xset(1). Default: 10 minutes. This is only suitable for VESA DPMS
compatible monitors, and may not be supported by all video drivers. It is
only enabled for screens that have the "DPMS" option set
(see the MONITOR section below).
- Option "OffTime" "time"
- sets the inactivity timeout for the off phase of DPMS mode.
time is in minutes, and the value can be changed at run-time with
xset(1). Default: 10 minutes. This is only suitable for VESA DPMS
compatible monitors, and may not be supported by all video drivers. It is
only enabled for screens that have the "DPMS" option set
(see the MONITOR section below).
- Option "MaxClients"
"integer"
- Set the maximum number of clients allowed to connect to the X server.
Acceptable values are 64, 128, 256 or 512.
- Option "NoPM" "boolean"
- Disables something to do with power management events. Default: PM enabled
on platforms that support it.
- Option "Xinerama" "boolean"
- enable or disable XINERAMA extension. Default is disabled.
- Option "IndirectGLX"
"boolean"
- enable or disable indirect GLX contexts. Indirect GLX contexts are
disabled by default.
- Option "DRI2" "boolean"
- enable or disable DRI2. DRI2 is disabled by default.
- Option "GlxVisuals" "string"
- This option controls how many GLX visuals the GLX modules sets up. The
default value is typical, which will setup up a typical subset of
the GLXFBConfigs provided by the driver as GLX visuals. Other options are
minimal, which will set up the minimal set allowed by the GLX
specification and all which will setup GLX visuals for all
GLXFBConfigs.
- Option "UseDefaultFontPath"
"boolean"
- Include the default font path even if other paths are specified in
xorg.conf. If enabled, other font paths are included as well. Enabled by
default.
- Option "IgnoreABI" "boolean"
- Allow modules built for a different, potentially incompatible version of
the X server to load. Disabled by default.
- Option "AutoAddDevices"
"boolean"
- If this option is disabled, then no devices will be added from the HAL or
udev backends. Enabled by default.
- Option "AutoEnableDevices"
"boolean"
- If this option is disabled, then the devices will be added (and the
DevicePresenceNotify event sent), but not enabled, thus leaving policy up
to the client. Enabled by default.
- Option "AutoAddGPU"
"boolean"
- If this option is disabled, then no GPU devices will be added from the
udev backend. Enabled by default. (May need to be disabled to setup
Xinerama).
- Option "Log" "string"
- This option controls whether the log is flushed and/or synced to disk
after each message. Possible values are flush or sync. Unset
by default.
The Module section is used to specify which Xorg server modules should be
loaded. This section is ignored when the Xorg server is built in static form.
The type of modules normally loaded in this section are Xorg server extension
modules. Most other module types are loaded automatically when they are needed
via other mechanisms. The Module section is optional, as are all of the
entries that may be specified in it.
Entries in this section may be in two forms. The first and most
commonly used form is an entry that uses the Load keyword, as
described here:
- Load "modulename"
- This instructs the server to load the module called modulename. The
module name given should be the module's standard name, not the module
file name. The standard name is case-sensitive, and does not include the
“lib” or “cyg” prefixes, or the
“.so” or “.dll” suffixes.
Example: the DRI extension module can be loaded with the
following entry:
Load "dri"
- Disable "modulename"
- This instructs the server to not load the module called modulename.
Some modules are loaded by default in the server, and this overrides that
default. If a Load instruction is given for the same module, it
overrides the Disable instruction and the module is loaded. The
module name given should be the module's standard name, not the module
file name. As with the Load instruction, the standard name is
case-sensitive, and does not include the "lib" prefix, or the
".a", ".o", or ".so" suffixes.
The second form of entry is a SubSection, with the
subsection name being the module name, and the contents of the
SubSection being Options that are passed to the module when it
is loaded.
Example: the extmod module (which contains a miscellaneous group
of server extensions) can be loaded, with the XFree86-DGA extension disabled
by using the following entry:
SubSection "extmod"
Option "omit XFree86-DGA"
EndSubSection
Modules are searched for in each directory specified in the
ModulePath search path, and in the drivers, extensions, input,
internal, and multimedia subdirectories of each of those directories. In
addition to this, operating system specific subdirectories of all the above
are searched first if they exist.
To see what extension modules are available, check the extensions
subdirectory under:
/usr/local/lib/xorg/modules
The “extmod”, “dbe”,
“dri”, “dri2”, “glx”, and
“record” extension modules are loaded automatically, if they
are present, unless disabled with "Disable" entries. It is
recommended that at very least the “extmod” extension module
be loaded. If it isn't, some commonly used server extensions (like the SHAPE
extension) will not be available.
The Extensions section is used to specify which X11 protocol extensions
should be enabled or disabled. The Extensions section is optional, as
are all of the entries that may be specified in it.
Entries in this section are listed as Option statements with the
name of the extension as the first argument, and a boolean value as the
second. The extension name is case-sensitive, and matches the form shown in
the output of "Xorg -extension ?".
Example: the MIT-SHM extension can be disabled with the
following entry:
Section "Extensions"
Option "MIT-SHM" "Disable"
EndSection
The config file may have multiple InputDevice sections. Recent X servers
employ HAL or udev backends for input device enumeration and input
hotplugging. It is usually not necessary to provide InputDevice
sections in the xorg.conf if hotplugging is in use (i.e. AutoAddDevices is
enabled). If hotplugging is enabled, InputDevice sections using the
mouse, kbd and vmmouse driver will be ignored.
If hotplugging is disabled, there will normally be at least two:
one for the core (primary) keyboard and one for the core pointer. If either
of these two is missing, a default configuration for the missing ones will
be used. In the absence of an explicitly specified core input device, the
first InputDevice marked as CorePointer (or
CoreKeyboard) is used. If there is no match there, the first
InputDevice that uses the “mouse” (or
“kbd”) driver is used. The final fallback is to use built-in
default configurations. Currently the default configuration may not work as
expected on all platforms.
InputDevice sections have the following format:
Section "InputDevice"
Identifier "name"
Driver "inputdriver"
options
...
EndSection
The Identifier and Driver entries are required in
all InputDevice sections. All other entries are optional.
The Identifier entry specifies the unique name for this
input device. The Driver entry specifies the name of the driver to
use for this input device. When using the loadable server, the input driver
module "inputdriver" will be loaded for each active
InputDevice section. An InputDevice section is considered
active if it is referenced by an active ServerLayout section, if it
is referenced by the -keyboard or -pointer command line
options, or if it is selected implicitly as the core pointer or keyboard
device in the absence of such explicit references. The most commonly used
input drivers are evdev(4) on Linux systems, and kbd(4) and
mousedrv(4) on other platforms.
InputDevice sections recognise some driver-independent
Options, which are described here. See the individual input driver
manual pages for a description of the device-specific options.
- Option "AutoServerLayout"
"boolean"
- Always add the device to the ServerLayout section used by this instance of
the server. This affects implied layouts as well as explicit layouts
specified in the configuration and/or on the command line.
- Option "CorePointer"
- Deprecated, see Floating
- Option "CoreKeyboard"
- Deprecated, see Floating
- Option "AlwaysCore"
"boolean"
- Deprecated, see Floating
- Option "SendCoreEvents"
"boolean"
- Deprecated, see Floating
- Option "Floating" "boolean"
- When enabled, the input device is set up floating and does not report
events through any master device or control a cursor. The device is only
available to clients using the X Input Extension API. This option is
disabled by default. The options CorePointer, CoreKeyboard,
AlwaysCore, and SendCoreEvents, are the inverse of option
Floating (i.e. SendCoreEvents "on" is equivalent
to Floating "off" ).
This option controls the startup behavior only, a device may
be reattached or set floating at runtime.
- Option "TransformationMatrix" "a
b c d e
f g h
i"
- Specifies the 3x3 transformation matrix for absolute input devices. The
input device will be bound to the area given in the matrix. In most
configurations, "a" and "e" specify the width and
height of the area the device is bound to, and "c" and
"f" specify the x and y offset of the area. The value range is 0
to 1, where 1 represents the width or height of all root windows together,
0.5 represents half the area, etc. The values represent a 3x3 matrix, with
the first, second and third group of three values representing the first,
second and third row of the matrix, respectively. The identity matrix is
"1 0 0 0 1 0 0 0 1".
For pointing devices, the following options control how the pointer is
accelerated or decelerated with respect to physical device motion. Most of
these can be adjusted at runtime, see the xinput(1) man page for details. Only
the most important acceleration options are discussed here.
- Option "AccelerationProfile"
"integer"
- Select the profile. In layman's terms, the profile constitutes the
"feeling" of the acceleration. More formally, it defines how the
transfer function (actual acceleration as a function of current device
velocity and acceleration controls) is constructed. This is mainly a
matter of personal preference.
0 classic (mostly compatible)
-1 none (only constant deceleration is applied)
1 device-dependent
2 polynomial (polynomial function)
3 smooth linear (soft knee, then linear)
4 simple (normal when slow, otherwise accelerated)
5 power (power function)
6 linear (more speed, more acceleration)
7 limited (like linear, but maxes out at threshold)
- Option "ConstantDeceleration"
"real"
- Makes the pointer go deceleration times slower than normal. Most
useful for high-resolution devices. A value between 0 and 1 will speed up
the pointer.
- Option "AdaptiveDeceleration"
"real"
- Allows to actually decelerate the pointer when going slow. At most, it
will be adaptive deceleration times slower. Enables precise pointer
placement without sacrificing speed.
- Option "AccelerationScheme"
"string"
- Selects the scheme, which is the underlying algorithm.
predictable default algorithm (behaving more predictable)
lightweight old acceleration code (as specified in the X protocol spec)
none no acceleration or deceleration
- Option "AccelerationNumerator"
"integer"
- Option "AccelerationDenominator"
"integer"
- Set numerator and denominator of the acceleration factor. The acceleration
factor is a rational which, together with threshold, can be used to tweak
profiles to suit the users needs. The simple and limited
profiles use it directly (i.e. they accelerate by the factor), for other
profiles it should hold that a higher acceleration factor leads to a
faster pointer. Typically, 1 is unaccelerated and values up to 5 are
sensible.
- Option "AccelerationThreshold"
"integer"
- Set the threshold, which is roughly the velocity (usually device units per
10 ms) required for acceleration to become effective. The precise effect
varies with the profile however.
The config file may have multiple InputClass sections. These sections are
optional and are used to provide configuration for a class of input devices as
they are automatically added. An input device can match more than one
InputClass section. Each class can override settings from a previous
class, so it is best to arrange the sections with the most generic matches
first.
InputClass sections have the following format:
Section "InputClass"
Identifier "name"
entries
...
options
...
EndSection
The Identifier entry is required in all InputClass
sections. All other entries are optional.
The Identifier entry specifies the unique name for this
input class. The Driver entry specifies the name of the driver to use
for this input device. After all classes have been examined, the
"inputdriver" module from the first Driver entry
will be enabled when using the loadable server.
When an input device is automatically added, its characteristics
are checked against all InputClass sections. Each section can contain
optional entries to narrow the match of the class. If none of the optional
entries appear, the InputClass section is generic and will match any
input device. If more than one of these entries appear, they all must match
for the configuration to apply.
There are two types of match entries used in InputClass
sections. The first allows various tokens to be matched against attributes
of the device. An entry can be constructed to match attributes from
different devices by separating arguments with a '|' character. Multiple
entries of the same type may be supplied to add multiple matching conditions
on the same attribute. For example:
Section "InputClass"
Identifier "My Class"
# product string must contain example and
# either gizmo or gadget
MatchProduct "example"
MatchProduct "gizmo|gadget"
NoMatchDriver "drivername"
...
EndSection
- MatchProduct "matchproduct"
- This entry can be used to check if the substring
"matchproduct" occurs in the device's product name.
- MatchVendor "matchvendor"
- This entry can be used to check if the substring
"matchvendor" occurs in the device's vendor name.
- MatchDevicePath "matchdevice"
- This entry can be used to check if the device file matches the
"matchdevice" pathname pattern.
- MatchOS "matchos"
- This entry can be used to check if the operating system matches the
case-insensitive "matchos" string. This entry is only
supported on platforms providing the uname(2) system call.
- MatchPnPID "matchpnp"
- The device's Plug and Play (PnP) ID can be checked against the
"matchpnp" shell wildcard pattern.
- MatchUSBID "matchusb"
- The device's USB ID can be checked against the "matchusb"
shell wildcard pattern. The ID is constructed as lowercase hexadecimal
numbers separated by a ':'. This is the same format as the lsusb(8)
program.
- MatchDriver "matchdriver"
- Check the case-sensitive string "matchdriver" against the
currently configured driver of the device. Ordering of sections using this
entry is important since it will not match unless the driver has been set
by the config backend or a previous InputClass section.
- MatchTag "matchtag"
- This entry can be used to check if tags assigned by the config backend
matches the "matchtag" pattern. A match is found if at
least one of the tags given in "matchtag" matches at
least one of the tags assigned by the backend.
- MatchLayout "matchlayout"
- Check the case-sensitive string "matchlayout" against the
currently active ServerLayout section. The empty string
"" matches an implicit layout which appears if no named
ServerLayout sections have been found.
The above directives have equivalents for negative matching with
the NoMatchProduct, NoMatchVendor, NoMatchDevicePath,
NoMatchOS, NoMatchPnPID, NoMatchUSBID,
NoMatchDriver, NoMatchTag, and NoMatchLayout
directives. These NoMatch directives match if the subsequent match is not
met by the device.
The second type of entry is used to match device types. These
entries take a boolean argument similar to Option entries.
- MatchIsKeyboard "bool"
- MatchIsPointer "bool"
- MatchIsJoystick "bool"
- MatchIsTablet "bool"
- MatchIsTabletPad "bool"
- MatchIsTouchpad "bool"
- MatchIsTouchscreen "bool"
When an input device has been matched to the InputClass
section, any Option entries are applied to the device. One
InputClass specific Option is recognized. See the
InputDevice section above for a description of the remaining
Option entries.
- Option "Ignore" "boolean"
- This optional entry specifies that the device should be ignored entirely,
and not added to the server. This can be useful when the device is handled
by another program and no X events should be generated.
The config file may have multiple OutputClass sections. These sections
are optional and are used to provide configuration for a class of output
devices as they are automatically added. An output device can match more than
one OutputClass section. Each class can override settings from a
previous class, so it is best to arrange the sections with the most generic
matches first.
OutputClass sections have the following format:
Section "OutputClass"
Identifier "name"
entries
...
EndSection
The Identifier entry is required in all OutputClass
sections. All other entries are optional.
The Identifier entry specifies the unique name for this
output class. The Driver entry specifies the name of the driver to
use for this output device. After all classes have been examined, the
"outputdriver" module from the first Driver entry
will be enabled when using the loadable server.
When an output device is automatically added, its characteristics
are checked against all OutputClass sections. Each section can
contain optional entries to narrow the match of the class. If none of the
optional entries appear, the OutputClass section is generic and will
match any output device. If more than one of these entries appear, they all
must match for the configuration to apply.
The following list of tokens can be matched against attributes of
the device. An entry can be constructed to match attributes from different
devices by separating arguments with a '|' character.
For example:
Section "OutputClass"
Identifier "My Class"
# kernel driver must be either foo or bar
MatchDriver "foo|bar"
...
EndSection
- MatchDriver "matchdriver"
- Check the case-sensitive string "matchdriver" against the
kernel driver of the device.
When an output device has been matched to the OutputClass
section, any Option entries are applied to the device. One
OutputClass specific Option is recognized. See the
Device section below for a description of the remaining Option
entries.
- Option "PrimaryGPU"
"boolean"
- This option specifies that the matched device should be treated as the
primary GPU, replacing the selection of the GPU used as output by the
firmware. If multiple output devices match an OutputClass section with the
PrimaryGPU option set, the first one enumerated becomes the primary
GPU.
A OutputClass Section may contain ModulePath
entries. When an output device matches an OutputClass section, any
ModulePath entries in that OutputClass are pre-pended to the
search path for loadable Xorg server modules. See ModulePath in the
Files section for more info.
The config file may have multiple Device sections. There must be at least
one, for the video card being used.
Device sections have the following format:
Section "Device"
Identifier "name"
Driver "driver"
entries
...
EndSection
The Identifier and Driver entries are required in
all Device sections. All other entries are optional.
The Identifier entry specifies the unique name for this
graphics device. The Driver entry specifies the name of the driver to
use for this graphics device. When using the loadable server, the driver
module "driver" will be loaded for each active
Device section. A Device section is considered active if it is
referenced by an active Screen section.
Device sections recognise some driver-independent entries
and Options, which are described here. Not all drivers make use of
these driver-independent entries, and many of those that do don't require
them to be specified because the information is auto-detected. See the
individual graphics driver manual pages for further information about this,
and for a description of the device-specific options. Note that most of the
Options listed here (but not the other entries) may be specified in
the Screen section instead of here in the Device section.
- BusID "bus-id"
- This specifies the bus location of the graphics card. For PCI/AGP cards,
the bus-id string has the form
PCI:bus@domain:device:function
(e.g., “PCI:1@0:0:0” might be appropriate for an AGP card).
The "@domain" part can be left out for PCI domain 0. This field
is usually optional in single-head configurations when using the primary
graphics card. In multi-head configurations, or when using a secondary
graphics card in a single-head configuration, this entry is mandatory. Its
main purpose is to make an unambiguous connection between the device
section and the hardware it is representing. This information can usually
be found by running the pciaccess tool scanpci.
- Screen number
- This option is mandatory for cards where a single PCI entity can drive
more than one display (i.e., multiple CRTCs sharing a single graphics
accelerator and video memory). One Device section is required for
each head, and this parameter determines which head each of the
Device sections applies to. The legal values of number range
from 0 to one less than the total number of heads per entity. Most drivers
require that the primary screen (0) be present.
- Chipset "chipset"
- This usually optional entry specifies the chipset used on the graphics
board. In most cases this entry is not required because the drivers will
probe the hardware to determine the chipset type. Don't specify it unless
the driver-specific documentation recommends that you do.
- Ramdac "ramdac-type"
- This optional entry specifies the type of RAMDAC used on the graphics
board. This is only used by a few of the drivers, and in most cases it is
not required because the drivers will probe the hardware to determine the
RAMDAC type where possible. Don't specify it unless the driver-specific
documentation recommends that you do.
- DacSpeed speed
- DacSpeed speed-8 speed-16 speed-24 speed-32
- This optional entry specifies the RAMDAC speed rating (which is usually
printed on the RAMDAC chip). The speed is in MHz. When one value is given,
it applies to all framebuffer pixel sizes. When multiple values are given,
they apply to the framebuffer pixel sizes 8, 16, 24 and 32 respectively.
This is not used by many drivers, and only needs to be specified when the
speed rating of the RAMDAC is different from the defaults built in to
driver, or when the driver can't auto-detect the correct defaults. Don't
specify it unless the driver-specific documentation recommends that you
do.
- Clocks clock ...
- specifies the pixel that are on your graphics board. The clocks are in
MHz, and may be specified as a floating point number. The value is stored
internally to the nearest kHz. The ordering of the clocks is important. It
must match the order in which they are selected on the graphics board.
Multiple Clocks lines may be specified, and each is concatenated to
form the list. Most drivers do not use this entry, and it is only required
for some older boards with non-programmable clocks. Don't specify this
entry unless the driver-specific documentation explicitly recommends that
you do.
- ClockChip "clockchip-type"
- This optional entry is used to specify the clock chip type on graphics
boards which have a programmable clock generator. Only a few Xorg drivers
support programmable clock chips. For details, see the appropriate driver
manual page.
- VideoRam mem
- This optional entry specifies the amount of video ram that is installed on
the graphics board. This is measured in kBytes. In most cases this is not
required because the Xorg server probes the graphics board to determine
this quantity. The driver-specific documentation should indicate when it
might be needed.
- MemBase baseaddress
- This optional entry specifies the memory base address of a graphics
board's linear frame buffer. This entry is not used by many drivers, and
it should only be specified if the driver-specific documentation
recommends it.
- IOBase baseaddress
- This optional entry specifies the IO base address. This entry is not used
by many drivers, and it should only be specified if the driver-specific
documentation recommends it.
- ChipID id
- This optional entry specifies a numerical ID representing the chip type.
For PCI cards, it is usually the device ID. This can be used to override
the auto-detection, but that should only be done when the driver-specific
documentation recommends it.
- ChipRev rev
- This optional entry specifies the chip revision number. This can be used
to override the auto-detection, but that should only be done when the
driver-specific documentation recommends it.
- MatchSeat seat-id
- Only apply this Device section if X server was started with
-seat seat-id option.
- Option "ModeDebug" "boolean"
- Enable printing of additional debugging information about modesetting to
the server log.
- Option "PreferCloneMode"
"boolean"
- If enabled, bring up monitors of a screen in clone mode instead of
horizontal extended layout by default. (Defaults to off; the video driver
can change the default value, but this option can always override it)
- Options
- Option flags may be specified in the Device sections. These include
driver-specific options and driver-independent options. The former are
described in the driver-specific documentation. Some of the latter are
described below in the section about the Screen section, and they
may also be included here.
Nobody wants to say how this works. Maybe nobody knows ...
The config file may have multiple Monitor sections. There should normally
be at least one, for the monitor being used, but a default configuration will
be created when one isn't specified.
Monitor sections have the following format:
Section "Monitor"
Identifier "name"
entries
...
EndSection
The only mandatory entry in a Monitor section is the
Identifier entry.
The Identifier entry specifies the unique name for this
monitor. The Monitor section may be used to provide information about
the specifications of the monitor, monitor-specific Options, and
information about the video modes to use with the monitor.
With RandR 1.2-enabled drivers, monitor sections may be tied to
specific outputs of the video card. Using the name of the output defined by
the video driver plus the identifier of a monitor section, one associates a
monitor section with an output by adding an option to the Device section in
the following format:
Option "Monitor-outputname"
"monitorsection"
(for example, Option "Monitor-VGA" "VGA
monitor" for a VGA output)
In the absence of specific association of monitor sections to
outputs, if a monitor section is present the server will associate it with
an output to preserve compatibility for previous single-head
configurations.
Specifying video modes is optional because the server will use the
DDC or other information provided by the monitor to automatically configure
the list of modes available. When modes are specified explicitly in the
Monitor section (with the Mode, ModeLine, or
UseModes keywords), built-in modes with the same names are not
included. Built-in modes with different names are, however, still implicitly
included, when they meet the requirements of the monitor.
The entries that may be used in Monitor sections are
described below.
- VendorName "vendor"
- This optional entry specifies the monitor's manufacturer.
- ModelName "model"
- This optional entry specifies the monitor's model.
- HorizSync horizsync-range
- gives the range(s) of horizontal sync frequencies supported by the
monitor. horizsync-range may be a comma separated list of either
discrete values or ranges of values. A range of values is two values
separated by a dash. By default the values are in units of kHz. They may
be specified in MHz or Hz if MHz or Hz is added to the end
of the line. The data given here is used by the Xorg server to determine
if video modes are within the specifications of the monitor. This
information should be available in the monitor's handbook. If this entry
is omitted, a default range of 28-33kHz is used.
- VertRefresh vertrefresh-range
- gives the range(s) of vertical refresh frequencies supported by the
monitor. vertrefresh-range may be a comma separated list of either
discrete values or ranges of values. A range of values is two values
separated by a dash. By default the values are in units of Hz. They may be
specified in MHz or kHz if MHz or kHz is added to the end of
the line. The data given here is used by the Xorg server to determine if
video modes are within the specifications of the monitor. This information
should be available in the monitor's handbook. If this entry is omitted, a
default range of 43-72Hz is used.
- DisplaySize width height
- This optional entry gives the width and height, in millimetres, of the
picture area of the monitor. If given this is used to calculate the
horizontal and vertical pitch (DPI) of the screen.
- Gamma gamma-value
- Gamma red-gamma green-gamma blue-gamma
- This is an optional entry that can be used to specify the gamma correction
for the monitor. It may be specified as either a single value or as three
separate RGB values. The values should be in the range 0.1 to 10.0, and
the default is 1.0. Not all drivers are capable of using this
information.
- UseModes "modesection-id"
- Include the set of modes listed in the Modes section called
modesection-id. This makes all of the modes defined in that section
available for use by this monitor.
- Mode "name"
- This is an optional multi-line entry that can be used to provide
definitions for video modes for the monitor. In most cases this isn't
necessary because the built-in set of VESA standard modes will be
sufficient. The Mode keyword indicates the start of a multi-line
video mode description. The mode description is terminated with the
EndMode keyword. The mode description consists of the following
entries:
- DotClock clock
- is the dot (pixel) clock rate to be used for the mode.
- HTimings hdisp hsyncstart hsyncend htotal
- specifies the horizontal timings for the mode.
- VTimings vdisp vsyncstart vsyncend vtotal
- specifies the vertical timings for the mode.
- Flags "flag" ...
- specifies an optional set of mode flags, each of which is a separate
string in double quotes. "Interlace" indicates that the
mode is interlaced. "DoubleScan" indicates a mode where
each scanline is doubled. "+HSync" and
"-HSync" can be used to select the polarity of the HSync
signal. "+VSync" and "-VSync" can be
used to select the polarity of the VSync signal.
"Composite" can be used to specify composite sync on
hardware where this is supported. Additionally, on some hardware,
"+CSync" and "-CSync" may be used to
select the composite sync polarity.
- HSkew hskew
- specifies the number of pixels (towards the right edge of the screen) by
which the display enable signal is to be skewed. Not all drivers use this
information. This option might become necessary to override the default
value supplied by the server (if any). “Roving” horizontal
lines indicate this value needs to be increased. If the last few pixels on
a scan line appear on the left of the screen, this value should be
decreased.
- VScan vscan
- specifies the number of times each scanline is painted on the screen. Not
all drivers use this information. Values less than 1 are treated as 1,
which is the default. Generally, the "DoubleScan"
Flag mentioned above doubles this value.
- ModeLine "name"
mode-description
- This entry is a more compact version of the Mode entry, and it also
can be used to specify video modes for the monitor. This is a single line
format for specifying video modes. In most cases this isn't necessary
because the built-in set of VESA standard modes will be sufficient.
The mode-description is in four sections, the
first three of which are mandatory. The first is the dot (pixel) clock. This
is a single number specifying the pixel clock rate for the mode in MHz. The
second section is a list of four numbers specifying the horizontal timings.
These numbers are the hdisp, hsyncstart, hsyncend, and
htotal values. The third section is a list of four numbers specifying
the vertical timings. These numbers are the vdisp, vsyncstart,
vsyncend, and vtotal values. The final section is a list of
flags specifying other characteristics of the mode. Interlace indicates
that the mode is interlaced. DoubleScan indicates a mode where each
scanline is doubled. +HSync and -HSync can be used to select the
polarity of the HSync signal. +VSync and -VSync can be used to
select the polarity of the VSync signal. Composite can be used to
specify composite sync on hardware where this is supported. Additionally, on
some hardware, +CSync and -CSync may be used to select the
composite sync polarity. The HSkew and VScan options mentioned
above in the Mode entry description can also be used here.
- Option "DPMS" "bool"
- This option controls whether the server should enable the DPMS extension
for power management for this screen. The default is to enable the
extension.
- Option "SyncOnGreen" "bool"
- This option controls whether the video card should drive the sync signal
on the green color pin. Not all cards support this option, and most
monitors do not require it. The default is off.
- Option "Primary" "bool"
- This optional entry specifies that the monitor should be treated as the
primary monitor. (RandR 1.2-supporting drivers only)
- Option "PreferredMode"
"name"
- This optional entry specifies a mode to be marked as the preferred initial
mode of the monitor. (RandR 1.2-supporting drivers only)
- Option "ZoomModes" "name
name ..."
- This optional entry specifies modes to be marked as zoom modes. It is
possible to switch to the next and previous mode via
Ctrl+Alt+Keypad-Plus and Ctrl+Alt+Keypad-Minus. All these
keypad available modes are selected from the screen mode list. This list
is a copy of the compatibility output monitor mode list. Since this output
is the output connected to the lowest dot-area monitor, as determined from
its largest size mode, that monitor defines the available zoom modes.
(RandR 1.2-supporting drivers only)
- Option "Position" "x
y"
- This optional entry specifies the position of the monitor within the X
screen. (RandR 1.2-supporting drivers only)
- Option "LeftOf" "output"
- This optional entry specifies that the monitor should be positioned to the
left of the output (not monitor) of the given name. (RandR 1.2-supporting
drivers only)
- Option "RightOf" "output"
- This optional entry specifies that the monitor should be positioned to the
right of the output (not monitor) of the given name. (RandR 1.2-supporting
drivers only)
- Option "Above" "output"
- This optional entry specifies that the monitor should be positioned above
the output (not monitor) of the given name. (RandR 1.2-supporting drivers
only)
- Option "Below" "output"
- This optional entry specifies that the monitor should be positioned below
the output (not monitor) of the given name. (RandR 1.2-supporting drivers
only)
- Option "Enable" "bool"
- This optional entry specifies whether the monitor should be turned on at
startup. By default, the server will attempt to enable all connected
monitors. (RandR 1.2-supporting drivers only)
- Option "DefaultModes" "bool"
- This optional entry specifies whether the server should add supported
default modes to the list of modes offered on this monitor. By default,
the server will add default modes; you should only disable this if you can
guarantee that EDID will be available at all times, or if you have added
custom modelines which the server can use. (RandR 1.2-supporting drivers
only)
- Option "MinClock"
"frequency"
- This optional entry specifies the minimum dot clock, in kHz, that is
supported by the monitor.
- Option "MaxClock"
"frequency"
- This optional entry specifies the maximum dot clock, in kHz, that is
supported by the monitor.
- Option "Ignore" "bool"
- This optional entry specifies that the monitor should be ignored entirely,
and not reported through RandR. This is useful if the hardware reports the
presence of outputs that don't exist. (RandR 1.2-supporting drivers
only)
- Option "Rotate" "rotation"
- This optional entry specifies the initial rotation of the given monitor.
Valid values for rotation are "normal", "left",
"right", and "inverted". (RandR 1.2-supporting drivers
only)
The config file may have multiple Modes sections, or none. These sections
provide a way of defining sets of video modes independently of the
Monitor sections. Monitor sections may include the definitions
provided in these sections by using the UseModes keyword. In most cases
the Modes sections are not necessary because the built-in set of VESA
standard modes will be sufficient.
Modes sections have the following format:
Section "Modes"
Identifier "name"
entries
...
EndSection
The Identifier entry specifies the unique name for this set
of mode descriptions. The other entries permitted in Modes sections
are the Mode and ModeLine entries that are described above in
the Monitor section.
The config file may have multiple Screen sections. There must be at least
one, for the “screen” being used. A “screen”
represents the binding of a graphics device (Device section) and a
monitor (Monitor section). A Screen section is considered
“active” if it is referenced by an active ServerLayout
section or by the -screen command line option. If neither of those is
present, the first Screen section found in the config file is
considered the active one.
Screen sections have the following format:
Section "Screen"
Identifier "name"
Device "devid"
GPUDevice "devid"
Monitor "monid"
entries
...
SubSection "Display"
entries
...
EndSubSection
...
EndSection
The Identifier entry is mandatory. All others are
optional.
The Identifier entry specifies the unique name for this
screen. The Screen section provides information specific to the whole
screen, including screen-specific Options. In multi-head
configurations, there will be multiple active Screen sections, one
for each head. The entries available for this section are:
- Device "device-id"
- This entry specifies the Device section to be used for this screen.
When multiple graphics cards are present, this is what ties a specific
card to a screen. The device-id must match the Identifier of
a Device section in the config file.
- GPUDevice "device-id"
- This entry specifies the Device section to be used as a secondary
GPU device for this screen. When multiple graphics cards are present, this
is what ties a specific secondary card to a screen. The device-id
must match the Identifier of a Device section in the config
file. This can be specified up to 4 times for a single screen.
- Monitor "monitor-id"
- specifies which monitor description is to be used for this screen. If a
Monitor name is not specified, a default configuration is used.
Currently the default configuration may not function as expected on all
platforms.
- VideoAdaptor "xv-id"
- specifies an optional Xv video adaptor description to be used with this
screen.
- DefaultDepth depth
- specifies which color depth the server should use by default. The
-depth command line option can be used to override this. If neither
is specified, the default depth is driver-specific, but in most cases is
8.
- DefaultFbBpp bpp
- specifies which framebuffer layout to use by default. The -fbbpp
command line option can be used to override this. In most cases the driver
will chose the best default value for this. The only case where there is
even a choice in this value is for depth 24, where some hardware supports
both a packed 24 bit framebuffer layout and a sparse 32 bit framebuffer
layout.
- MatchSeat seat-id
- Only apply this Screen section if X server was started with
-seat seat-id option.
- Options
- Various Option flags may be specified in the Screen section.
Some are driver-specific and are described in the driver documentation.
Others are driver-independent, and will eventually be described here.
- Option "Accel"
- Enables 2D hardware acceleration. This option is on by default, but it may
be necessary to turn it off if there are bugs in the driver. There are
many options to disable specific accelerated operations, listed below.
Note that disabling an operation will have no effect if the operation is
not accelerated (whether due to lack of support in the hardware or in the
driver).
- Option "GlxVendorLibrary"
"string"
- This option specifies a space-separated list of OpenGL vendor libraries to
use for the screen. This may be used to select an alternate implementation
for development, debugging, or alternate feature sets. Default: mesa.
- Option "InitPrimary"
"boolean"
- Use the Int10 module to initialize the primary graphics card. Normally,
only secondary cards are soft-booted using the Int10 module, as the
primary card has already been initialized by the BIOS at boot time.
Default: false.
- Option "NoInt10" "boolean"
- Disables the Int10 module, a module that uses the int10 call to the BIOS
of the graphics card to initialize it. Default: false.
Each Screen section may optionally contain one or more
Display subsections. Those subsections provide depth/fbbpp specific
configuration information, and the one chosen depends on the depth and/or
fbbpp that is being used for the screen. The Display subsection
format is described in the section below.
Each Screen section may have multiple Display subsections. The
“active” Display subsection is the first that matches the
depth and/or fbbpp values being used, or failing that, the first that has
neither a depth or fbbpp value specified. The Display subsections are
optional. When there isn't one that matches the depth and/or fbbpp values
being used, all the parameters that can be specified here fall back to their
defaults.
Display subsections have the following format:
SubSection "Display"
Depth depth
entries
...
EndSubSection
- Depth depth
- This entry specifies what colour depth the Display subsection is to
be used for. This entry is usually specified, but it may be omitted to
create a match-all Display subsection or when wishing to match only
against the FbBpp parameter. The range of depth values that
are allowed depends on the driver. Most drivers support 8, 15, 16 and 24.
Some also support 1 and/or 4, and some may support other values (like 30).
Note: depth means the number of bits in a pixel that are actually
used to determine the pixel colour. 32 is not a valid depth value.
Most hardware that uses 32 bits per pixel only uses 24 of them to hold the
colour information, which means that the colour depth is 24, not 32.
- FbBpp bpp
- This entry specifies the framebuffer format this Display subsection
is to be used for. This entry is only needed when providing depth 24
configurations that allow a choice between a 24 bpp packed framebuffer
format and a 32bpp sparse framebuffer format. In most cases this entry
should not be used.
- Weight red-weight green-weight blue-weight
- This optional entry specifies the relative RGB weighting to be used for a
screen is being used at depth 16 for drivers that allow multiple formats.
This may also be specified from the command line with the -weight
option (see Xorg(1)).
- Virtual xdim ydim
- This optional entry specifies the virtual screen resolution to be used.
xdim must be a multiple of either 8 or 16 for most drivers, and a
multiple of 32 when running in monochrome mode. The given value will be
rounded down if this is not the case. Video modes which are too large for
the specified virtual size will be rejected. If this entry is not present,
the virtual screen resolution will be set to accommodate all the valid
video modes given in the Modes entry. Some drivers/hardware
combinations do not support virtual screens. Refer to the appropriate
driver-specific documentation for details.
- ViewPort x0 y0
- This optional entry sets the upper left corner of the initial display.
This is only relevant when the virtual screen resolution is different from
the resolution of the initial video mode. If this entry is not given, then
the initial display will be centered in the virtual display area.
- Modes "mode-name" ...
- This optional entry specifies the list of video modes to use. Each
mode-name specified must be in double quotes. They must correspond
to those specified or referenced in the appropriate Monitor section
(including implicitly referenced built-in VESA standard modes). The server
will delete modes from this list which don't satisfy various requirements.
The first valid mode in this list will be the default display mode for
startup. The list of valid modes is converted internally into a circular
list. It is possible to switch to the next mode with
Ctrl+Alt+Keypad-Plus and to the previous mode with
Ctrl+Alt+Keypad-Minus. When this entry is omitted, the valid modes
referenced by the appropriate Monitor section will be used. If the
Monitor section contains no modes, then the selection will be taken
from the built-in VESA standard modes.
- Visual "visual-name"
- This optional entry sets the default root visual type. This may also be
specified from the command line (see the Xserver(1) man page). The
visual types available for depth 8 are (default is
PseudoColor):
StaticGray
GrayScale
StaticColor
PseudoColor
TrueColor
DirectColor
The visual type available for the depths 15, 16 and 24
are (default is TrueColor):
Not all drivers support DirectColor at these depths.
The visual types available for the depth 4 are (default is
StaticColor):
StaticGray
GrayScale
StaticColor
PseudoColor
The visual type available for the depth 1 (monochrome) is
StaticGray.
- Black red green blue
- This optional entry allows the “black” colour to be
specified. This is only supported at depth 1. The default is black.
- White red green blue
- This optional entry allows the “white” colour to be
specified. This is only supported at depth 1. The default is white.
- Options
- Option flags may be specified in the Display subsections. These may
include driver-specific options and driver-independent options. The former
are described in the driver-specific documentation. Some of the latter are
described above in the section about the Screen section, and they
may also be included here.
The config file may have multiple ServerLayout sections. A “server
layout” represents the binding of one or more screens (Screen
sections) and one or more input devices (InputDevice sections) to form
a complete configuration. In multi-head configurations, it also specifies the
relative layout of the heads. A ServerLayout section is considered
“active” if it is referenced by the -layout command line
option or by an Option "DefaultServerLayout" entry in the
ServerFlags section (the former takes precedence over the latter). If
those options are not used, the first ServerLayout section found in the
config file is considered the active one. If no ServerLayout sections
are present, the single active screen and two active (core) input devices are
selected as described in the relevant sections above.
ServerLayout sections have the following format:
Section "ServerLayout"
Identifier "name"
Screen "screen-id"
...
InputDevice "idev-id"
...
options
...
EndSection
Each ServerLayout section must have an Identifier
entry and at least one Screen entry.
The Identifier entry specifies the unique name for this
server layout. The ServerLayout section provides information specific
to the whole session, including session-specific Options. The
ServerFlags options (described above) may be specified here, and ones
given here override those given in the ServerFlags section.
The entries that may be used in this section are described
here.
- Screen screen-num "screen-id"
position-information
- One of these entries must be given for each screen being used in a
session. The screen-id field is mandatory, and specifies the
Screen section being referenced. The screen-num field is
optional, and may be used to specify the screen number in multi-head
configurations. When this field is omitted, the screens will be numbered
in the order that they are listed in. The numbering starts from 0, and
must be consecutive. The position-information field describes the
way multiple screens are positioned. There are a number of different ways
that this information can be provided:
- x y
- Absolute x y
- These both specify that the upper left corner's coordinates are
(x,y). The Absolute keyword is optional. Some older
versions of XFree86 (4.2 and earlier) don't recognise the Absolute
keyword, so it's safest to just specify the coordinates without it.
- RightOf "screen-id"
- LeftOf "screen-id"
- Above "screen-id"
- Below "screen-id"
- Relative "screen-id" x y
- These give the screen's location relative to another screen. The first
four position the screen immediately to the right, left, above or below
the other screen. When positioning to the right or left, the top edges are
aligned. When positioning above or below, the left edges are aligned. The
Relative form specifies the offset of the screen's origin (upper
left corner) relative to the origin of another screen.
- InputDevice "idev-id"
"option" ...
- One of these entries should be given for each input device being used in a
session. Normally at least two are required, one each for the core pointer
and keyboard devices. If either of those is missing, suitable
InputDevice entries are searched for using the method described
above in the INPUTDEVICE section. The idev-id field is
mandatory, and specifies the name of the InputDevice section being
referenced. Multiple option fields may be specified, each in double
quotes. The options permitted here are any that may also be given in the
InputDevice sections. Normally only session-specific input device
options would be used here. The most commonly used options are:
"CorePointer"
"CoreKeyboard"
"SendCoreEvents"
and the first two should normally be used to indicate the
core pointer and core keyboard devices respectively.
- MatchSeat seat-id
- Only apply this ServerLayout section if X server was started with
-seat seat-id option.
- Options
- In addition to the following, any option permitted in the
ServerFlags section may also be specified here. When the same
option appears in both places, the value given here overrides the one
given in the ServerFlags section.
- Option "IsolateDevice"
"bus-id"
- Restrict device resets to the specified bus-id. See the
BusID option (described in DEVICE SECTION, above) for the
format of the bus-id parameter. This option overrides
SingleCard, if specified. At present, only PCI devices can be
isolated in this manner.
- Option "SingleCard"
"boolean"
- As IsolateDevice, except that the bus ID of the first device in the
layout is used.
Here is an example of a ServerLayout section for a dual
headed configuration with two mice:
Section "ServerLayout"
Identifier "Layout 1"
Screen "MGA 1"
Screen "MGA 2" RightOf "MGA 1"
InputDevice "Keyboard 1" "CoreKeyboard"
InputDevice "Mouse 1" "CorePointer"
InputDevice "Mouse 2" "SendCoreEvents"
Option "BlankTime" "5"
EndSection
This optional section is used to provide some information for the Direct
Rendering Infrastructure. Details about the format of this section can be
found on-line at <https://dri.freedesktop.org/>.
The optional Vendor section may be used to provide vendor-specific
configuration information. Multiple Vendor sections may be present, and
they may contain an Identifier entry and multiple Option flags.
The data therein is not used in this release.
General: X(7), Xserver(1), Xorg(1), cvt(1),
gtf(1).
Not all modules or interfaces are available on all
platforms.
Display drivers: apm(4), ati(4), chips(4),
cirrus(4), cyrix(4), fbdev(4), glide(4),
glint(4), i128(4), i740(4), imstt(4),
intel(4), mga(4), neomagic(4), nv(4),
openchrome(4), r128(4), radeon(4), rendition(4),
savage(4), s3virge(4), siliconmotion(4), sis(4),
sisusb(4), sunbw2(4), suncg14(4), suncg3(4),
suncg6(4), sunffb(4), sunleo(4), suntcx(4),
tdfx(4), trident(4), tseng(4), vesa(4),
vmware(4), voodoo(4), wsfb(4), xgi(4),
xgixp(4).
Input drivers: acecad(4), citron(4),
elographics(4), evdev(4), fpit(4), joystick(4),
kbd(4), libinput(4), mousedrv(4), mutouch(4),
penmount(4), synaptics(4), vmmouse(4), void(4),
wacom(4).
Other modules and interfaces: exa(4), fbdevhw(4),
v4l(4).
This manual page was largely rewritten by David Dawes
<dawes@xfree86.org>.
Visit the GSP FreeBSD Man Page Interface. Output converted with ManDoc. |