IBLINKINFO(8) OpenIB Diagnostics IBLINKINFO(8)

IBLINKINFO - report link info for all links in the fabric

iblinkinfo <options>

iblinkinfo reports link info for each port in an IB fabric, node by node. Optionally, iblinkinfo can do partial scans and limit its output to parts of a fabric.

--down, -d Print only nodes which have a port in the "Down" state.

--line, -l Print all information for each link on one line. Default is to print a header with the node information and then a list for each port (useful for grep'ing output).

--additional, -p Print additional port settings (<LifeTime>,<HoqLife>,<VLStallCount>)

--switches-only Show only switches in output.

--cas-only Show only CAs in output.

The node to start a partial scan can be specified with the following addresses.

--port-guid, -G <port_guid> Specify a port_guid

-D, --Direct <dr_path> The address specified is a directed route

Examples:
   -D "0"          # self port
   -D "0,1,2,1,4"  # out via port 1, then 2, ...
   (Note the second number in the path specified must match the port being
   used.  This can be specified using the port selection flag '-P' or the
   port found through the automatic selection process.)


Note: For switches results are printed for all ports not just switch port 0.

--switch, -S <port_guid> same as "-G". (provided only for backward compatibility)

How much of the scan to be printed can be controled with the following.

--all, -a Print all nodes found in a partial fabric scan. Normally a partial fabric scan will return only the node specified. This option will print the other nodes found as well.

--hops, -n <hops> Specify the number of hops away from a specified node to scan. This is useful to expand a partial fabric scan beyond the node specified.

--load-cache <filename> Load and use the cached ibnetdiscover data stored in the specified filename. May be useful for outputting and learning about other fabrics or a previous state of a fabric.

--diff <filename> Load cached ibnetdiscover data and do a diff comparison to the current network or another cache. A special diff output for ibnetdiscover output will be displayed showing differences between the old and current fabric. By default, the following are compared for differences: switches, channel adapters, routers, and port connections.

--diffcheck <key(s)> Specify what diff checks should be done in the --diff option above. Comma separate multiple diff check key(s). The available diff checks are: sw = switches, ca = channel adapters, router = routers, port = port connections, lid = lids, nodedesc = node descriptions. Note that port, lid, and nodedesc are checked only for the node types that are specified (e.g. sw, ca, router). If port is specified alongside lid or nodedesc, remote port lids and node descriptions will also be compared.

--filterdownports <filename> Filter downports indicated in a ibnetdiscover cache. If a port was previously indicated as down in the specified cache, and is still down, do not output it in the resulting output. This option may be particularly useful for environments where switches are not fully populated, thus much of the default iblinkinfo info is considered unuseful. See ibnetdiscover for information on caching ibnetdiscover output.

-C, --Ca <ca_name> use the specified ca_name.

-P, --Port <ca_port> use the specified ca_port.

Multiple port/Multiple CA support: when no IB device or port is specified (see the "local umad parameters" below), the libibumad library selects the port to use by the following criteria:
1.
the first port that is ACTIVE.
2.
if not found, the first port that is UP (physical link up).

If a port and/or CA name is specified, the libibumad library attempts to fulfill the user request, and will fail if it is not possible.

For example:

ibaddr                 # use the first port (criteria #1 above)
ibaddr -C mthca1       # pick the best port from "mthca1" only.
ibaddr -P 2            # use the second (active/up) port from the first available IB device.
ibaddr -C mthca0 -P 2  # use the specified port only.




--config, -z <config_file> Specify alternate config file.
Default: /etc/infiniband-diags/ibdiag.conf


--outstanding_smps, -o <val>
Specify the number of outstanding SMP's which should be issued during the scan

Default: 2


--node-name-map <node-name-map> Specify a node name map.

This file maps GUIDs to more user friendly names. See FILES section.


-t, --timeout <timeout_ms> override the default timeout for the solicited mads.

-y, --m_key <key>
use the specified M_key for requests. If non-numeric value (like 'x') is specified then a value will be prompted for.

-e
show send and receive errors (timeouts and others)

-h, --help show the usage message

-v, --verbose
increase the application verbosity level. May be used several times (-vv or -v -v -v)

-V, --version show the version info.

0 on success, -1 on failure to scan the fabric, 1 if check mode is used and inconsistencies are found.

/etc/infiniband-diags/ibdiag.conf

A global config file is provided to set some of the common options for all tools. See supplied config file for details.

The node name map is used to specify user friendly names for nodes in the output. GUIDs are used to perform the lookup.

This functionality is provided by the opensm-libs package. See opensm(8) for the file location for your installation.

Generically:

# comment
<guid> "<name>"


Example:

# IB1
# Line cards
0x0008f104003f125c "IB1 (Rack 11 slot 1   ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f125d "IB1 (Rack 11 slot 1   ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f10d2 "IB1 (Rack 11 slot 2   ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f10d3 "IB1 (Rack 11 slot 2   ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f10bf "IB1 (Rack 11 slot 12  ) ISR9288/ISR9096 Voltaire sLB-24D"
# Spines
0x0008f10400400e2d "IB1 (Rack 11 spine 1   ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e2e "IB1 (Rack 11 spine 1   ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e2f "IB1 (Rack 11 spine 1   ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e31 "IB1 (Rack 11 spine 2   ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e32 "IB1 (Rack 11 spine 2   ) ISR9288 Voltaire sFB-12D"
# GUID   Node Name
0x0008f10400411a08 "SW1  (Rack  3) ISR9024 Voltaire 9024D"
0x0008f10400411a28 "SW2  (Rack  3) ISR9024 Voltaire 9024D"
0x0008f10400411a34 "SW3  (Rack  3) ISR9024 Voltaire 9024D"
0x0008f104004119d0 "SW4  (Rack  3) ISR9024 Voltaire 9024D"


Ira Weiny
< ira.weiny@intel.com >


Search for    or go to Top of page |  Section 8 |  Main Index

Powered by GSP Visit the GSP FreeBSD Man Page Interface.