NAMESMPQUERY -QUERY INFINIBAND SUBNET MANAGEMENT ATTRIBUTESSYNOPSISsmpquery [options] <op> <dest dr_path|lid|guid> [op params]DESCRIPTIONsmpquery allows a basic subset of standard SMP queries including the following: node info, node description, switch info, port info. Fields are displayed in human readable format.OPTIONSCurrent supported operations (case insensitive) and their parameters:Nodeinfo (NI) <addr> Nodedesc (ND) <addr> Portinfo (PI) <addr> [<portnum>] # default port is zero PortInfoExtended (PIE) <addr> [<portnum>] Switchinfo (SI) <addr> PKeyTable (PKeys) <addr> [<portnum>] SL2VLTable (SL2VL) <addr> [<portnum>] VLArbitration (VLArb) <addr> [<portnum>] GUIDInfo (GI) <addr> MlnxExtPortInfo (MEPI) <addr> [<portnum>] # default port is zero
Addressing Flags-D, --Direct The address specified is a directed routeExamples: [options] -D [options] "0" # self port [options] -D [options] "0,1,2,1,4" # out via port 1, then 2, ... (Note the second number in the path specified must match the port being used. This can be specified using the port selection flag '-P' or the port found through the automatic selection process.) -G, --Guid The address specified is a Port GUID -L, --Lid The address specified is a LID -s, --sm_port <smlid> use 'smlid' as the target lid for SA queries. Port Selection flags-C, --Ca <ca_name> use the specified ca_name.-P, --Port <ca_port> use the specified ca_port. Local port SelectionMultiple port/Multiple CA support: when no IB device or port is specified (see the "local umad parameters" below), the libibumad library selects the port to use by the following criteria:
If a port and/or CA name is specified, the libibumad library attempts to fulfill the user request, and will fail if it is not possible. For example: ibaddr # use the first port (criteria #1 above) ibaddr -C mthca1 # pick the best port from "mthca1" only. ibaddr -P 2 # use the second (active/up) port from the first available IB device. ibaddr -C mthca0 -P 2 # use the specified port only. Debugging flags
-h, --help show the usage message
-V, --version show the version info. Configuration flags-t, --timeout <timeout_ms> override the default timeout for the solicited mads.--node-name-map <node-name-map> Specify a node name map. This file maps GUIDs to more user friendly names. See
FILES section.
--config, -z <config_file> Specify alternate config file. Default: /etc/infiniband-diags/ibdiag.conf
FILESCONFIG FILE/etc/infiniband-diags/ibdiag.confA global config file is provided to set some of the common options for all tools. See supplied config file for details. NODE NAME MAP FILE FORMATThe node name map is used to specify user friendly names for nodes in the output. GUIDs are used to perform the lookup.This functionality is provided by the opensm-libs package. See opensm(8) for the file location for your installation. Generically: # comment <guid> "<name>" Example: # IB1 # Line cards 0x0008f104003f125c "IB1 (Rack 11 slot 1 ) ISR9288/ISR9096 Voltaire sLB-24D" 0x0008f104003f125d "IB1 (Rack 11 slot 1 ) ISR9288/ISR9096 Voltaire sLB-24D" 0x0008f104003f10d2 "IB1 (Rack 11 slot 2 ) ISR9288/ISR9096 Voltaire sLB-24D" 0x0008f104003f10d3 "IB1 (Rack 11 slot 2 ) ISR9288/ISR9096 Voltaire sLB-24D" 0x0008f104003f10bf "IB1 (Rack 11 slot 12 ) ISR9288/ISR9096 Voltaire sLB-24D" # Spines 0x0008f10400400e2d "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB-12D" 0x0008f10400400e2e "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB-12D" 0x0008f10400400e2f "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB-12D" 0x0008f10400400e31 "IB1 (Rack 11 spine 2 ) ISR9288 Voltaire sFB-12D" 0x0008f10400400e32 "IB1 (Rack 11 spine 2 ) ISR9288 Voltaire sFB-12D" # GUID Node Name 0x0008f10400411a08 "SW1 (Rack 3) ISR9024 Voltaire 9024D" 0x0008f10400411a28 "SW2 (Rack 3) ISR9024 Voltaire 9024D" 0x0008f10400411a34 "SW3 (Rack 3) ISR9024 Voltaire 9024D" 0x0008f104004119d0 "SW4 (Rack 3) ISR9024 Voltaire 9024D" EXAMPLES
SEE ALSOsmpdump (8)AUTHOR