SMP_CONF_GENERAL(8) |
SMP_UTILS |
SMP_CONF_GENERAL(8) |
smp_conf_general - invoke CONFIGURE GENERAL SMP function
smp_conf_general [--connect=CO] [--expected=EX]
[--help] [--hex] [--inactivity=IN]
[--interface=PARAMS] [--nexus=NE] [--open=OP]
[--power=PD] [--raw] [--reduced=RE]
[--sa=SAS_ADDR] [--ssp=CTL] [--verbose]
[--version] SMP_DEVICE[,N]
Sends a SAS Serial Management Protocol (SMP) CONFIGURE GENERAL function request
to an SMP target. The SMP target is identified by the SMP_DEVICE and
the --sa=SAS_ADDR. Depending on the interface, the SAS_ADDR may
be deduced from the SMP_DEVICE. The mpt interface uses
SMP_DEVICE to identify a HBA (an SMP initiator) and needs the
additional ,N to differentiate between HBAs if there are multiple
present.
Mandatory arguments to long options are mandatory for short options as well.
- -c, --connect=CO
- sets the "update STP maximum connect time limit" flag and the
corresponding "STP maximum connect time limit" field to
CO. Unit of CO is 100 microseconds. A CO of zero is
taken to mean no maximum connection time limit.
- -E, --expected=EX
- set the 'expected expander change count' field in the SMP request. The
value EX is from 0 to 65535 inclusive with 0 being the default
value. When EX is greater than zero then if the value doesn't match
the expander change count of the SMP target (i.e. the expander) when the
request arrives then the target ignores the request and sets a function
result of "invalid expander change count" in the response.
- -h, --help
- output the usage message then exit.
- -H, --hex
- output the response (less the CRC field) in hexadecimal.
- -i, --inactivity=IN
- sets the "update STP bus inactivity time limit" flag and the
corresponding "STP bus inactivity time limit" field to
IN. Unit of IN is 100 microseconds. A IN of zero is
taken to mean no bus inactivity time limit.
- -I, --interface=PARAMS
- interface specific parameters. In this case "interface" refers
to the path through the operating system to the SMP initiator. See the
smp_utils man page for more information.
- -n, --nexus=NE
- sets the "update STP SMP I_T nexus loss time" flag and the
corresponding "STP SMP I_T nexus loss time" field to NE.
Unit of NE is one millisecond. A NE of zero is taken to mean
a vendor specific amount of time; a NE of 65535 means the port
shall never recognize an I_T nexus loss.
- -o, --open=OP
- sets the "update STP reject to open limit" flag and the
corresponding "STP reject to open limit" field to OP.
Unit of OP is 10 microseconds.
- -p, --power=PD
- sets the "update power done timeout" flag and the corresponding
"power doen timeout" field to PD. Unit of PD is 1
second. A PD value of 0 is interpreted as don't change the current
value. The maximum value of PD is 255 and means the time limit is
vendor specific.
- -r, --raw
- send the response (less the CRC field) to stdout in binary. All error
messages are sent to stderr.
- -R, --reduced=RE
- sets the "update Initial time to reduced functionality" flag and
the corresponding "Initial time to reduced functionality" field
to RE. Unit of RE is 100 milliseconds. The maximum permitted
RE value is 255 which corresponds to 25.5 seconds.
- -s, --sa=SAS_ADDR
- specifies the SAS address of the SMP target device. Typically this is an
expander. This option may not be needed if the SMP_DEVICE has the
target's SAS address within it. The SAS_ADDR is in decimal but most
SAS addresses are shown in hexadecimal. To give a number in hexadecimal
either prefix it with '0x' or put a trailing 'h' on it.
- -S, --ssp=CTL
- sets the "update SSP time limit" flag and the corresponding
"SSP maximum connect time limit" field to CTL. Unit of
CTL is 100 microseconds. A CTL of zero is taken to meanthat
there is no SSP connect time limit.
- -v, --verbose
- increase the verbosity of the output. Can be used multiple times
- -V, --version
- print the version string and then exit.
The SMP CONFIGURE GENERAL function was introduced in SAS-2 .
Written by Douglas Gilbert.
Report bugs to <dgilbert at interlog dot com>.
Copyright © 2006-2015 Douglas Gilbert
This software is distributed under a FreeBSD license. There is NO warranty; not
even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
smp_utils, smp_rep_general(smp_utils)