NAMEupsdrvctl - UPS driver controllerSYNOPSISupsdrvctl -hupsdrvctl [OPTIONS] {start | stop | shutdown} [ups] DESCRIPTIONupsdrvctl provides a uniform interface for controlling your UPS drivers. You should use upsdrvctl instead of direct calls to the drivers whenever possible.When used properly, upsdrvctl lets you maintain identical startup scripts across multiple systems with different UPS configurations. OPTIONS-hDisplay the help text.
-r directory If starting a driver, this value will direct it to
chroot(2) into directory. This can be useful when securing
systems.
This may be set in the ups.conf with "chroot" in the global section. -t Enable testing mode. This also enables debug mode.
Testing mode makes upsdrvctl display the actions it would execute without
actually doing them. Use this to test out your configuration without actually
doing anything to your UPS drivers. This may be helpful when defining the
sdorder directive in your ups.conf(5).
-u username If starting a driver, this value will direct it to
setuid(2) to the user id associated with username.
If the driver is started as root without specifying this value, it will use the username that was compiled into the binary. This defaults to "nobody", and is far from ideal. This may be set in ups.conf with "user" in the global section. -D Raise the debug level. Use this multiple times for
additional details.
COMMANDSupsdrvctl supports three commands - start, stop and shutdown. They take an optional argument which is a UPS name from ups.conf(5). Without that argument, they operate on every UPS that is currently configured.start Start the UPS driver(s). In case of failure, further
attempts may be executed by using the maxretry and retrydelay
options - see ups.conf(5).
stop Stop the UPS driver(s).
shutdown Command the UPS driver(s) to run their shutdown sequence.
Drivers are stopped according to their sdorder value - see
ups.conf(5).
Warning this will probably power off your computers, so don’t play around with this option. Only use it when your systems are prepared to lose power. ENVIRONMENT VARIABLESNUT_CONFPATH is the path name of the directory that contains upsd.conf and other configuration files. If this variable is not set, upsdrvctl the driver use a built-in default, which is often /usr/local/ups/etc.DIAGNOSTICSupsdrvctl will return a nonzero exit code if it encounters an error while performing the desired operation. This will also happen if a driver takes longer than the maxstartdelay period to enter the background.SEE ALSOnutupsdrv(8), upsd(8), ups.conf(5)Internet resources:The NUT (Network UPS Tools) home page: http://www.networkupstools.org/