zmtrigger.pl - ZoneMinder External Trigger Script
This script is used to trigger and cancel alarms from external connections using
an arbitrary text based format.
This script offers generic solution to external triggering of
alarms. It can handle external connections via either internet socket, unix
socket or file/device interfaces. You can either use it 'as is' if you can
interface with the existing format, or override connections and channels to
customise it to your needs.
If enabled by the OPT_TRIGGERS option, Zoneminder service start
zmtrigger.pl which listens for control messages on TCP port 6802.
id|action|score|cause|text|showtext
- id
-
is the id number or name of the ZM monitor.
- action
-
Valid actions are 'on', 'off', 'cancel' or 'show' where
'on' forces an alarm condition on;
'off' forces an alarm condition off;
'cancel' negates the previous 'on' or 'off';
'show' updates the auxiliary text represented by the %Q
placeholder, which can optionally be added to the affected monitor's
timestamp label format.
Ordinarily you would use 'on' and 'cancel', 'off' would tend to be
used to suppress motion based events. Additionally 'on' and 'off' can
take an additional time offset, e.g. on+20 which automatically
cancel's the previous action after that number of seconds.
- score
-
is the score given to the alarm, usually to indicate it's
importance. For 'on' triggers it should be non-zero, otherwise it should
be zero.
- cause
-
is a 32 char max string indicating the reason for, or source of
the alarm e.g. 'Relay 1 open'. This is saved in the 'Cause' field of the
event. Ignored for 'off' or 'cancel' messages.
- text
-
is a 256 char max additional info field, which is saved in the
'Description' field of an event. Ignored for 'off' or 'cancel' messages.
- showtext
-
is up to 32 characters of text that can be displayed in the
timestamp that is added to images. The 'show' action is designed to
update this text without affecting alarms but the text is updated, if
present, for any of the actions. This is designed to allow external input
to appear on the images captured, for instance temperature or personnel
identity etc.
Note that multiple messages can be sent at once and should be LF or CRLF
delimited. This script is not necessarily intended to be a solution in
itself, but is intended to be used as 'glue' to help ZoneMinder interface
with other systems. It will almost certainly require some customisation
before you can make any use of it. If all you want to do is generate alarms
from external sources then using the ZoneMinder::SharedMem perl module is
likely to be easier.
3|on+10|1|motion|text|showtext
Triggers 'alarm' on camera #3 for 10 seconds with score=1,
cause='motion'.